An optical dilatometer is a non-contact device able to measure thermal expansions or sintering kinetics of any kind of materials, unlike traditional push rod dilatometer, it can push up to the dilatometric softening of the specimen. It is a device for measuring changes in the dimensions of a specimen, optically, the achieved resolution can result in greater values than those of a conventional pushrod dilatometer. A monochromatic light source, such as a laser, illuminates the specimen. Some of the light is reflected by the specimen and interferes with the incoming light, creating optical interference fringes. As the specimen contracts or expands, there is a proportional movement of the interference fringes, which can be measured using a camera system. The measurement resolution is determine

Property Value
dbo:abstract
  • An optical dilatometer is a non-contact device able to measure thermal expansions or sintering kinetics of any kind of materials, unlike traditional push rod dilatometer, it can push up to the dilatometric softening of the specimen. It is a device for measuring changes in the dimensions of a specimen, optically, the achieved resolution can result in greater values than those of a conventional pushrod dilatometer. A monochromatic light source, such as a laser, illuminates the specimen. Some of the light is reflected by the specimen and interferes with the incoming light, creating optical interference fringes. As the specimen contracts or expands, there is a proportional movement of the interference fringes, which can be measured using a camera system. The measurement resolution is determined by the wavelength of the light, and is typically 0.5 μm for blue light. Optical dilatometers are used to measure thermal expansion. The optical dilatometer is in fact complementary to the traditional higher resolution push rod dilatometer when it comes to measure dimensional changes of materials, as a function of temperature, and no contact between specimen and instrument is required. (en)
dbo:wikiPageExternalLink
dbo:wikiPageID
  • 11748275 (xsd:integer)
dbo:wikiPageLength
  • 7258 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1049548002 (xsd:integer)
dbo:wikiPageWikiLink
dcterms:subject
gold:hypernym
rdf:type
rdfs:comment
  • An optical dilatometer is a non-contact device able to measure thermal expansions or sintering kinetics of any kind of materials, unlike traditional push rod dilatometer, it can push up to the dilatometric softening of the specimen. It is a device for measuring changes in the dimensions of a specimen, optically, the achieved resolution can result in greater values than those of a conventional pushrod dilatometer. A monochromatic light source, such as a laser, illuminates the specimen. Some of the light is reflected by the specimen and interferes with the incoming light, creating optical interference fringes. As the specimen contracts or expands, there is a proportional movement of the interference fringes, which can be measured using a camera system. The measurement resolution is determine (en)
rdfs:label
  • Optical dilatometer (en)
owl:sameAs
prov:wasDerivedFrom
foaf:isPrimaryTopicOf
is dbo:knownFor of
is dbo:wikiPageRedirects of
is dbo:wikiPageWikiLink of
is dbp:knownFor of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License