An Entity of Type: Thing, from Named Graph: http://dbpedia.org, within Data Space: dbpedia.org

Holotomography (HT) is a laser technique to measure three-dimensional refractive index (RI) tomogram of a microscopic sample such as biological cells and tissues. Because the RI can serve as an intrinsic imaging contrast for transparent or phase objects, measurements of RI tomograms can provide label-free quantitative imaging of microscopic phase objects. In order to measure 3-D RI tomogram of samples, HT employs the principle of holographic imaging and inverse scattering. Typically, multiple 2D holographic images of a sample are measured at various illumination angles, employing the principle of interferometric imaging. Then, a 3D RI tomogram of the sample is reconstructed from these multiple 2D holographic images by inversely solving light scattering in the sample.

Property Value
dbo:abstract
  • Η ολοτομογραφία (αγγλ. Holotomography), συντομογραφικά ως HT, είναι σύγχρονη τεχνική λέιζερ για τη μέτρηση τρισδιάστατης τομογραφίας -βάσει του δείκτη διάθλασης (RI)- σε διάφορα μικροσκοπικά δείγματα, όπως λ.χ. βιολογικά κύτταρα και ιστοί. Επειδή ο δείκτης διάθλασης μπορεί να χρησιμεύσει ως εγγενής αντίθεση απεικόνισης για διαφανή αντικείμενα ή φάσεις, οι μετρήσεις αυτού του τύπου τομογραφιών μπορούν να παρέχουν ποσοτική απεικόνιση αντικειμένων μικροσκοπικής φάσης, χωρίς ετικέτα. Προκειμένου να μετρηθεί το τρισδιάστατο τομογράφημα δειγμάτων, ο δείκτης χρησιμοποιεί την αρχή της ολογραφικής απεικόνισης και της αντίστροφης σκέδασης. Συνήθως, πολλαπλές δισδιάστατες ολογραφικές εικόνες ενός δείγματος μετρώνται σε διάφορες γωνίες φωτισμού, χρησιμοποιώντας την αρχή της ενδομετρικής απεικόνισης. Στη συνέχεια, ένα τρισδιάστατο τομογράφημα του δείγματος (με αυτή τη νέα τεχνική) ανακατασκευάζεται από αυτές τις πολλαπλές δισδιάστατες ολογραφικές εικόνες λύνοντας αντίστροφα τη σκέδαση φωτός στο δείγμα. Η πρώτη θεωρητική πρόταση για την ολοτομογραφία παρουσιάστηκε από τον δρ. Emil Wolf και η πρώτη πειραματική επίδειξη παρουσιάστηκε από τους Fercher et al. Από τη δεκαετία του 2000, οι τεχνικές Ολοτομογραφίας μελετήθηκαν και εφαρμόστηκαν εκτενώς στους τομείς της βιολογίας και της ιατρικής, από διάφορες ερευνητικές ομάδες, συμπεριλαμβανομένου του Εργαστηρίου Φασματοσκοπίας, στο Τεχνολογικό Ινστιτούτο Μασαχουσέτης (MIT). Τόσο οι τεχνικές εξελίξεις όσο και οι εφαρμογές του HT έχουν προχωρήσει σημαντικά. Το 2012 ιδρύθηκε η πρώτη εμπορική εταιρεία με την ονομασία Nanolive ακολουθούμενη αργότερα από την εταιρεία Tomocube, το 2014. (el)
  • Holotomography (HT) is a laser technique to measure three-dimensional refractive index (RI) tomogram of a microscopic sample such as biological cells and tissues. Because the RI can serve as an intrinsic imaging contrast for transparent or phase objects, measurements of RI tomograms can provide label-free quantitative imaging of microscopic phase objects. In order to measure 3-D RI tomogram of samples, HT employs the principle of holographic imaging and inverse scattering. Typically, multiple 2D holographic images of a sample are measured at various illumination angles, employing the principle of interferometric imaging. Then, a 3D RI tomogram of the sample is reconstructed from these multiple 2D holographic images by inversely solving light scattering in the sample. (en)
dbo:thumbnail
dbo:wikiPageExternalLink
dbo:wikiPageID
  • 53999565 (xsd:integer)
dbo:wikiPageLength
  • 15313 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1068814887 (xsd:integer)
dbo:wikiPageWikiLink
dbp:wikiPageUsesTemplate
dcterms:subject
rdfs:comment
  • Holotomography (HT) is a laser technique to measure three-dimensional refractive index (RI) tomogram of a microscopic sample such as biological cells and tissues. Because the RI can serve as an intrinsic imaging contrast for transparent or phase objects, measurements of RI tomograms can provide label-free quantitative imaging of microscopic phase objects. In order to measure 3-D RI tomogram of samples, HT employs the principle of holographic imaging and inverse scattering. Typically, multiple 2D holographic images of a sample are measured at various illumination angles, employing the principle of interferometric imaging. Then, a 3D RI tomogram of the sample is reconstructed from these multiple 2D holographic images by inversely solving light scattering in the sample. (en)
  • Η ολοτομογραφία (αγγλ. Holotomography), συντομογραφικά ως HT, είναι σύγχρονη τεχνική λέιζερ για τη μέτρηση τρισδιάστατης τομογραφίας -βάσει του δείκτη διάθλασης (RI)- σε διάφορα μικροσκοπικά δείγματα, όπως λ.χ. βιολογικά κύτταρα και ιστοί. (el)
rdfs:label
  • Ολοτομογραφία (el)
  • Holotomography (en)
owl:sameAs
prov:wasDerivedFrom
foaf:depiction
foaf:isPrimaryTopicOf
is dbo:knownFor of
is dbo:wikiPageWikiLink of
is dbp:knownFor of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License