An Entity of Type: software, from Named Graph: http://dbpedia.org, within Data Space: dbpedia.org:8891

Optoelectronic plethysmography is a method to evaluate ventilation through an external measurement of the chest wall surface motion. A number of small reflective markers are placed on the thoraco-abdominal surface by hypoallergenic adhesive tape. A system for human motion analysis measures the three-dimensional coordinates of these markers and the enclosed volume is computed by connecting the points to form triangles.

Property Value
dbo:abstract
  • يعد التصوير الطبي البصري الإلكتروني طريقة لتقييم التهوية من خلال قياس خارجي لحركة سطح جدار الصدر. يتم وضع عدد من العلامات العاكسة الصغيرة على سطح الصدر الصدري بشريط لاصق مضاد للحساسية. يقيس نظام تحليل الحركة البشرية الإحداثيات ثلاثية الأبعاد لهذه العلامات ويتم حساب الحجم المرفق عن طريق توصيل النقاط لتشكيل مثلثات. من الممكن من خلال التصوير الطبي البصري الإلكتروني الحصول على اختلافات حجم جدار الصدر بأكمله ومقصوراته المختلفة. يمكن تصميم جدار الصدر على أنه يتألف من ثلاثة أقسام مختلفة: القفص الصدري، القفص الصدري البطني، والبطن. هذا النموذج هو الأنسب لدراسة حركية جدار الصدر في معظم الظروف، بما في ذلك التمرين. ويأخذ في الاعتبار حقيقة أن الأجزاء التي يطبقها الرئتين والحجاب الحاجز من القفص الصدري تتعرض لضغوط مختلفة إلى حد كبير على سطحها الداخلي أثناء الإلهام، وأن الحجاب الحاجز يعمل مباشرة فقط على القفص الصدري البطني، وأن تعمل العضلات الملهمة غير الغشائية إلى حد كبير على القفص الصدري. يتم تعريف تغيير حجم البطن على أنه الحجم الذي اجتاحه جدار البطن. يمكن استخدام تخطيط التحجيم الإلكتروني البصري باتباع بروتوكولات قياس مختلفة، تم تطويرها خصيصًا لتطبيقات مختلفة وحالات تجريبية وسريرية مختلفة. في الترتيب المصمم للتحليل في وضعي الجلوس والوقوف، يتم ترتيب 89 علامة على سطح الصدر الصدري. يمكن استخدام تخطيط التحجم الإلكتروني البصري الإلكتروني أيضًا في وضعيات الاستلقاء والضعف. تم استخدام التصوير الطبي البصري الإلكتروني لدراسة حركية جدار الصدر في الأشخاص الأصحاء أثناء التمرين، المرضى الذين يعانون من مرض داء الانسداد الرئوي المزمن، المرضى الذين يعانون من اضطرابات عصبية عضلية وفي وحدة العناية المركزة. تم الحصول على التحقق من صحة هذه الطريقة من خلال مقارنة التغيرات في حجم الرئة التي تم الحصول عليها بواسطة أجهزة قياس التدفق الحجمي وقياس التدفق ومجموع الأحجام الكلية لجدار الصدر عن طريق التصوير الطبي البصري الإلكتروني خلال المناورات المختلفة. (ar)
  • Optoelectronic plethysmography is a method to evaluate ventilation through an external measurement of the chest wall surface motion. A number of small reflective markers are placed on the thoraco-abdominal surface by hypoallergenic adhesive tape. A system for human motion analysis measures the three-dimensional coordinates of these markers and the enclosed volume is computed by connecting the points to form triangles. From optoelectronic plethysmography it is thus possible to obtain volume variations of the entire chest wall and its different compartments. The chest wall can be modeled as being composed of three different compartments: pulmonary rib cage, abdominal rib cage, and the abdomen. This model is the most appropriate for the study of chest wall kinematics in the majority of conditions, including exercise. It takes into consideration the fact that the lung- and diaphragm-apposed parts of the rib cage are exposed to substantially different pressures on their inner surface during inspiration, that the diaphragm acts directly only on the abdominal rib cage, and that non-diaphragmatic inspiratory muscles act largely on the pulmonary rib cage. Abdominal volume change is defined as the volume swept by the abdominal wall. Optoelectronic plethysmography can be used following different measurement protocols, specifically developed for different applications and different experimental and clinical situations. In the arrangement designed for the analysis in sitting and standing positions, 89 markers are arranged on the thoraco-abdominal surface. Optoelectronic plethysmography can be used also in supine and prone positions. Optoelectronic plethysmography was used to study chest wall kinematics in healthy subjects during exercise, patients with Chronic Obstructive Pulmonary Disease, patients with neuromuscular disorders and in Intensive Care Unit. The validation of the method was obtained by comparing the lung volume changes obtained by Volumetric and Flow measuring Spirometers and chest wall total volumes by optoelectronic plethysmography during different maneuvers. (en)
  • La pletismografia optoelettronica è un metodo per misurare i parametri di ventilazione tramite la misura delle variazioni della superficie toracica. (it)
dbo:wikiPageID
  • 2768512 (xsd:integer)
dbo:wikiPageLength
  • 5193 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1034701971 (xsd:integer)
dbo:wikiPageWikiLink
dbp:name
  • Optoelectronic plethysmography (en)
dbp:purpose
  • measure ventilation through an external measurement of the chest wall (en)
dbp:wikiPageUsesTemplate
dcterms:subject
gold:hypernym
rdf:type
rdfs:comment
  • La pletismografia optoelettronica è un metodo per misurare i parametri di ventilazione tramite la misura delle variazioni della superficie toracica. (it)
  • يعد التصوير الطبي البصري الإلكتروني طريقة لتقييم التهوية من خلال قياس خارجي لحركة سطح جدار الصدر. يتم وضع عدد من العلامات العاكسة الصغيرة على سطح الصدر الصدري بشريط لاصق مضاد للحساسية. يقيس نظام تحليل الحركة البشرية الإحداثيات ثلاثية الأبعاد لهذه العلامات ويتم حساب الحجم المرفق عن طريق توصيل النقاط لتشكيل مثلثات. تم الحصول على التحقق من صحة هذه الطريقة من خلال مقارنة التغيرات في حجم الرئة التي تم الحصول عليها بواسطة أجهزة قياس التدفق الحجمي وقياس التدفق ومجموع الأحجام الكلية لجدار الصدر عن طريق التصوير الطبي البصري الإلكتروني خلال المناورات المختلفة. (ar)
  • Optoelectronic plethysmography is a method to evaluate ventilation through an external measurement of the chest wall surface motion. A number of small reflective markers are placed on the thoraco-abdominal surface by hypoallergenic adhesive tape. A system for human motion analysis measures the three-dimensional coordinates of these markers and the enclosed volume is computed by connecting the points to form triangles. (en)
rdfs:label
  • تصوير طبي بصري إلكتروني (ar)
  • Pletismografia optoelettronica (it)
  • Optoelectronic plethysmography (en)
owl:sameAs
prov:wasDerivedFrom
foaf:isPrimaryTopicOf
is dbo:wikiPageWikiLink of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License