This HTML5 document contains 389 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dbthttp://dbpedia.org/resource/Template:
n52http://bn.dbpedia.org/resource/
wikipedia-enhttp://en.wikipedia.org/wiki/
n29http://pa.dbpedia.org/resource/
dbpedia-lmohttp://lmo.dbpedia.org/resource/
dbpedia-bghttp://bg.dbpedia.org/resource/
dbpedia-fihttp://fi.dbpedia.org/resource/
dbrhttp://dbpedia.org/resource/
n54http://my.dbpedia.org/resource/
dbpedia-mshttp://ms.dbpedia.org/resource/
dbpedia-arhttp://ar.dbpedia.org/resource/
dbpedia-ethttp://et.dbpedia.org/resource/
dbpedia-hehttp://he.dbpedia.org/resource/
dbpedia-frhttp://fr.dbpedia.org/resource/
n17http://commons.wikimedia.org/wiki/Special:FilePath/
dctermshttp://purl.org/dc/terms/
dbpedia-cshttp://cs.dbpedia.org/resource/
rdfshttp://www.w3.org/2000/01/rdf-schema#
n48http://lv.dbpedia.org/resource/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n39http://d-nb.info/gnd/
n5http://dbpedia.org/resource/File:
dbphttp://dbpedia.org/property/
dbpedia-eohttp://eo.dbpedia.org/resource/
n26http://www.ece.utexas.edu/~grady/
xsdhhttp://www.w3.org/2001/XMLSchema#
dbpedia-idhttp://id.dbpedia.org/resource/
dbpedia-ukhttp://uk.dbpedia.org/resource/
dbohttp://dbpedia.org/ontology/
dbpedia-pnbhttp://pnb.dbpedia.org/resource/
dbpedia-srhttp://sr.dbpedia.org/resource/
dbpedia-vihttp://vi.dbpedia.org/resource/
dbpedia-pthttp://pt.dbpedia.org/resource/
dbpedia-skhttp://sk.dbpedia.org/resource/
n42http://dbpedia.org/resource/Glossary_of_engineering:
dbpedia-jahttp://ja.dbpedia.org/resource/
dbchttp://dbpedia.org/resource/Category:
dbpedia-dehttp://de.dbpedia.org/resource/
dbpedia-plhttp://pl.dbpedia.org/resource/
dbpedia-ruhttp://ru.dbpedia.org/resource/
yagohttp://dbpedia.org/class/yago/
dbpedia-rohttp://ro.dbpedia.org/resource/
wikidatahttp://www.wikidata.org/entity/
dbpedia-nlhttp://nl.dbpedia.org/resource/
goldhttp://purl.org/linguistics/gold/
n62https://global.dbpedia.org/id/
yago-reshttp://yago-knowledge.org/resource/
dbpedia-ithttp://it.dbpedia.org/resource/
n23http://hi.dbpedia.org/resource/
dbpedia-cahttp://ca.dbpedia.org/resource/
provhttp://www.w3.org/ns/prov#
foafhttp://xmlns.com/foaf/0.1/
dbpedia-simplehttp://simple.dbpedia.org/resource/
n22http://su.dbpedia.org/resource/
dbpedia-zhhttp://zh.dbpedia.org/resource/
dbpedia-kohttp://ko.dbpedia.org/resource/
dbpedia-glhttp://gl.dbpedia.org/resource/
dbpedia-fahttp://fa.dbpedia.org/resource/
dbpedia-trhttp://tr.dbpedia.org/resource/
dbpedia-eshttp://es.dbpedia.org/resource/
freebasehttp://rdf.freebase.com/ns/
owlhttp://www.w3.org/2002/07/owl#
dbpedia-kahttp://ka.dbpedia.org/resource/

Statements

Subject Item
dbr:Amtrak's_25_Hz_traction_power_system
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Power_electronics
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Rotary_phase_converter
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Electric_power_distribution
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Electric_power_system
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Electrical_ballast
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Electrical_grid
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Electrical_measurements
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Electrical_substation
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Electricity_meter
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Energy_demand_management
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Energy_storage_as_a_service
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:List_of_dimensionless_quantities
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Cos_Phi_Meter
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Hydrargyrum_medium-arc_iodide_lamp
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Performance_and_modelling_of_AC_transmission
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Current_clamp
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Variable-frequency_drive
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Dynamic_demand_(electric_power)
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Index_of_electrical_engineering_articles
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Induction_motor
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Light_switch
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Power-voltage_curve
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Power-factor_correction
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:1977_IPSC_Handgun_World_Shoot
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Low_frequency_electromagnetic_compatibility
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Real_versus_nominal_value
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Electric_motor
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Electric_power
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Electric_power_quality
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Electric_power_transmission
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Electrical_characteristics_of_dynamic_loudspeakers
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Electricity_billing_in_the_UK
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Glossary_of_civil_engineering
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Glossary_of_electrical_and_electronics_engineering
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
n42:_M–Z
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:LED_lamp
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:V_curve
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Antenna_(radio)
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Loharinag_Pala_Hydropower_Project
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Compact_fluorescent_lamp
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Harmonics_(electrical_power)
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:PF
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageDisambiguates
dbr:Power_factor
Subject Item
dbr:Polarity_(mutual_inductance)
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Power_factor
rdf:type
yago:Content105809192 owl:Thing yago:PsychologicalFeature100023100 yago:Concept105835747 yago:WikicatElectricalParameters yago:Constant105858936 yago:Parameter105859071 yago:Idea105833840 yago:Quantity105855125 yago:Cognition100023271 yago:Abstraction100002137
rdfs:label
Leistungsfaktor Коэффициент мощности Współczynnik mocy 力率 역률 Fator de potência Factor de potencia Коефіцієнт потужності Factor de potència Facteur de puissance Arbeidsfactor Faktoro de povumo Power factor Fattore di potenza 功率因数 معامل القدرة Faktor daya listrik Účiník
rdfs:comment
De arbeidsfactor of vermogensfactor is de verhouding tussen het werkelijke vermogen en het schijnbare vermogen in een wisselspanningsinstallatie. Het schijnbare vermogen is het product van de effectieve waarde van de elektrische spanning en van de elektrische stroomsterkte, en wordt uitgedrukt in de eenheid voltampère: Het werkelijke vermogen is de per tijdseenheid overgebrachte hoeveelheid energie, het deel van het vermogen dat daadwerkelijk wordt omgezet in warmte en arbeid. Het wordt uitgedrukt in watt (W): En enginyeria elèctrica, el factor de potència d'un sistema de potència elèctric de corrent altern es defineix com la ràtio entre la potència real i la potència aparent. És un paràmetre sense dimensions i el seu interval va de -1 A +1. El seu símbol és FP o també cos φ. Les càrregues resistives pures tenen un FP=1, en canvi les càrregues inductives pures (inductives o capacitives) tenen un FP=0. 전기에는 직류와 교류가 존재하는데, 역률(영어: power factor)은 교류와 관계된다. 왜냐하면, 직류에서는 전압과 전류의 곱으로 전력이 되는데, 그 공식은 아래와 같이 나타낼 수 있다. P = 전력, V = 전압, I = 전류 직류에서는 위상이라는 개념이 없다. 하지만, 교류에서는 위상이 존재하며, 교류회로에서 역률은 (Active Power [단위 : W])과 (Apparent Power [단위 : VA])의 비를 말하는데, 이를 간단히 풀어서 해석하면, “전기설비에 걸리는 전압과 전류가 얼마나 효율적으로 일을 잘 하고 있는가?”로 나타내는 지표로도 활용된다. 역률은 유효전력을 피상전력(외관상의 전력)으로 나눈값이며, 교류 회로에서 전류와 전압의 위상차를 코사인 값(cosθ)으로 나타낸다. 직류에서는 전압과 전류만 곱하면 그것이 전력이었으나, 교류는 전압과 전류의 실효값을 곱한 피상전력이라는 것에 역률을 곱하여야 비로소 전력이 된다. 왜냐하면 직류처럼 일정한 흐름이 아닌, 정현파의 형태를 그리며 계속 지속적으로 변하기 때문이다. 즉, 직류처럼 일정한 값이 아닌, 계속 지속적으로 변하는 값이기 때문에 위상이 반드시 일치하지는 않는 것이다. (단, 위상각) In ingegneria elettrica, il fattore di potenza di un sistema elettrico a corrente alternata è il rapporto fra il modulo del vettore potenza attiva che alimenta un carico elettrico e il modulo del vettore potenza apparente che fluisce nel circuito. In un sistema con carichi lineari coincide con il coseno dell'angolo di sfasamento compreso tra i vettori tensione e corrente. È un numero adimensionale nell'intervallo chiuso tra -1 e 1. In quasi tutti i circuiti reali, la corrente è in ritardo rispetto alla tensione e la potenza apparente risulta quasi sempre maggiore della potenza attiva. Le facteur de puissance est une caractéristique d'un récepteur électrique qui rend compte de son efficacité pour consommer de la puissance lorsqu'il est traversé par un courant. Pour un dipôle électrique alimenté en régime de courant variable au cours du temps (sinusoïdal ou non), il est égal à la puissance active P consommée par ce dipôle, divisée par le produit des valeurs efficaces du courant I et de la tension U (puissance apparente S). Il est toujours compris entre 0 et 1. O fator de potência (FP) é uma relação entre potência ativa e potência reativa por consequência energia ativa e reativa. Ele pode ser usado para indicar se a proporção entre potência reativa e ativa está adequada. O fator de potência de um sistema elétrico qualquer, que está operando em corrente alternada (CA), é definido pela razão da potência real ou potência ativa pela potência total ou potência aparente. Um FP alto indica uma boa eficiência quanto ao uso de energia, significa dizer que grande parte da energia drenada é transformada em trabalho, inversamente a isso um fator de potência baixo indica que você não está aproveitando plenamente a energia drenada (entende-se por "energia drenada" a energia que você compra da concessionaria). Współczynnik mocy, – stosunek mocy czynnej do mocy pozornej, czyli stosunek mocy użytecznej do iloczynu napięcia i prądu. Powszechnie dziś stosowane w elektrotechnice pojęcie współczynnika mocy wprowadził pod koniec XIX wieku uczony polskiego pochodzenia Michał Doliwo-Dobrowolski pracujący wówczas w niemieckim koncernie AEG. W obwodach zasilanych napięciem sinusoidalnie zmiennym, a powodujących powstawanie prądu o przebiegach okresowych niesinusoidalnych, rozpatruje się bardzo często dwie składowe współczynnika mocy: Całkowity współczynnik mocy wynosi wtedy: gdzie: Коефіціє́нт поту́жності — безрозмірна фізична величина, що означує споживача змінного електричного струму з точки зору наявності в навантаженні реактивної складової. Коефіцієнт потужності показує, наскільки зсувається по фазі змінний струм, що протікає крізь навантаження, щодо прикладеної до нього напруги. Чисельно коефіцієнт потужності дорівнює косинусу цього фазового зсуву. Коэффицие́нт мо́щности — безразмерная физическая величина, характеризующая потребителя переменного электрического тока с точки зрения наличия в нагрузке реактивной составляющей и мощности искажения (собирательное название — неактивная мощность). Следует отличать понятие «коэффициент мощности» от понятия «косинус фи», который равен косинусу сдвига фазы переменного тока, протекающего через нагрузку, относительно приложенного к ней напряжения. Второе понятие используют в случае синусоидальных тока и напряжения, и только в этом случае оба понятия эквивалентны. معامل القدرة (Power Factor) هو النسبة بين إلى ، وهو مساوِ لجيب تمام زاوية الطور (cos_phi) - والتي هي فرق زاويتي الجهد والتيار. لذا فهو قيمة عددية ليس لها وحدة قياس تتراوح من الصفر إلى الواحد، في محطات القدرة يحبذ ويتم السعي إلى أن يكون معامل القدرة أكبر ما يمكن حيث أنه بزيادة درجة معامل القدرة يزداد مقدارالقدرة الفعالة وتنخفض القيمة أو وتتراوح قيم معاملات القدرة في محطات القدرة التي تعتمد نظام التيار المتردد الأحمال الكهربائية تقع في إحدى التصنيفات التالية: * مقاوِم Resistive * حثي Inductive * سعوي Capacitive Se define factor de potencia, f.d.p., de un circuito de corriente alterna, potencia activa, P, y la potencia aparente, S.​Da una medida de la capacidad de una carga de absorber potencia activa. Por esta razón, f.d.p = 1 en cargas puramente resistivas. Faktor daya listrik adalah nilai perbandingan antara dan . Rentang nilainya berkisar antara nol hingga satu. Faktor daya listrik dinyatakan dengan nilai cos φ. Pengamatan faktor daya listrik didasarkan pada jumlah arus listrik keseluruhan dalam suatu rangkaian listrik dan perbandingannya dengan jumlah arus yang terpakai. Pengambaran faktor daya dilakukan melalui sudut kosinus antara arus listrik dan tegangan listrik yang bekerja pada suatu . Faktor daya berguna untuk mengetahui tingkat efisiensi energi pada suatu beban listrik melalui nilai daya yang tidak terpakai dan terbuang sia-sia selama beban bekerja. Účiník je kosinus vzájemného fázového posuvu mezi proudem a napětím elektrického obvodu s harmonickými průběhy střídavých proudů a napětí či periodickými průběhy o jednotlivých harmonických složkách proudů a napětí. Účiník je poměrem činného a zdánlivého elektrického výkonu v obvodu střídavého proudu a napětí, vyjadřuje, jak velkou část zdánlivého výkonu přeměňuje obvod na činný výkon, tj. na součet užitečného výkonu a ztrát. Značka: Jednotka SI: - 功率因数(英語:power factor,縮寫:PF)又称功率因子,是交流電力系統中特有的物理量,是一負載所消耗的与其视在功率的比值,是0到1之間的無因次量。 有功功率代表一電路在特定時間作功的能力,视在功率是電壓和電流有效值的乘積。純電阻負載的视在功率等於有功功率,其功率因數為1。若負載是由電感、電容及電阻組成的線性負載,能量可能會在負載端及電源端往復流動,使得有功功率下降。若負載中有電感、電容及電阻以外的元件(非線性負載),會使得輸入電流的波形扭曲,也會使视在功率大於有功功率,這二種情形對應的功率因数會小於1。功率因数在一定程度上反映了发电机容量得以利用的比例,是合理用电的重要指标。 電力系統中,若一負載的功率因數較低,負載要產生相同功率輸出時所需要的電流就會提高。當電流提高時,電路系統的能量損失就會增加,而且電線及相關電力設備的容量也隨之增加。電力公司為了反映較大容量設備及浪費能量的成本,一般會對功率因數較低的工商業用戶以較高的電費費率來計算電費。 提高負載功率因數,使其接近1的技術稱為功率因數修正。低功率因數的線性負載(如感應馬達)可以藉由電感或電容組成的被動元件網路來提昇功因。非線性負載(如二極體)會使得輸入電流的波形扭曲,此情形可以由主動或被動的功率因數修正來抵消電流扭曲的影響,並且改善功因。功率因數修正設備可以位在中央變電站、分佈在電力系統中,或是放在耗能設備的內部。 力率(りきりつ、Power factor)は、交流電力の効率に関して定義された値であり、皮相電力に対する有効電力の割合である。料金計算などの電力の管理では、パーセントで表される。 Als Leistungsfaktor (auch Wirkleistungsfaktor) wird in der elektrischen Wechselstromtechnik das Verhältnis vom Betrag der Wirkleistung zur Scheinleistung bezeichnet. Das Verhältnis wird in folgender Formel ausgedrückt: Der Leistungsfaktor kann zwischen 0 und 1 liegen: In electrical engineering, the power factor of an AC power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. Real power is the average of the instantaneous product of voltage and current and represents the capacity of the electricity for performing work. Apparent power is the product of RMS current and voltage. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power may be greater than the real power, so more current flows in the circuit than would be required to transfer real power alone. A power factor magnitude of less than one indicates the voltage and current are not in phase, reducing the average produ La faktoro de povumo estas karakteriza grando de elektra ricevilo. Ĝi egalas al la kvociento de la aktiva povumo transdonita al la ricevilo per la ŝajna povumo. La valoro de estas ĉiam inter 0 kaj 1. Se la kurento kaj la tensio estas sinusaj funkcioj de la tempo, la faktoro de povumo egalas al la kosinuso de la inter la kurento kaj la tensio.
foaf:depiction
n17:Power_factor_75_2.png n17:Power_triangle_diagram.jpg n17:Power_Factor_General_Case.svg n17:Power_factor_0.7.svg n17:Power_factor_0.svg n17:Active_pfc_PSU_packaging.png n17:Condensatorenbatterij.jpg n17:Condensor_bank_150kV_-_75MVAR.jpg n17:Lagging-Leading.jpg n17:Blindleistungskompensation.svg
dcterms:subject
dbc:Engineering_ratios dbc:AC_power dbc:Electrical_engineering dbc:Electrical_parameters
dbo:wikiPageID
41568
dbo:wikiPageRevisionID
1124211251
dbo:wikiPageWikiLink
n5:Condensatorenbatterij.jpg dbr:Electric_arc_furnace dbr:Arc_furnace dbr:Power_electronics dbr:Thyristor dbr:Electronic_filter dbr:Energy_Star dbc:Engineering_ratios dbr:Static_VAR_compensator dbr:Synchronous_motor dbr:Non-linear dbr:Harmonic dbr:Reactance_(electronics) dbc:AC_power dbr:Rectifier n5:Condensor_bank_150kV_-_75MVAR.jpg dbr:Three-phase_electric_power dbr:Ammeter dbr:Magnetic_field n5:Active_pfc_PSU_packaging.png dbr:Capacitor dbr:United_States_Environmental_Protection_Agency dbr:Harmonics_(electrical_power) dbr:80_Plus dbr:Joule_heating dbr:Phase_(waves) dbr:Contactor dbc:Electrical_engineering dbr:Moving_coil_meter dbr:Watt dbr:High-voltage_direct_current dbr:Ratio dbr:European_Union dbr:Boost_converter dbr:Electric_motor n5:Power_Factor_General_Case.svg dbr:Rectifiers dbr:Peak-to-average_ratio dbr:Product_(mathematics) dbr:Ground_and_neutral dbr:Fluorescent_lamp dbr:Electric_field dbr:Volt-amperes n5:Power_triangle_diagram.jpg dbr:Root_mean_square n5:Power_factor_75_2.png dbr:Linear_time-invariant_system n5:Power_factor_0.7.svg n5:Power_factor_0.svg dbr:Voltmeter dbr:Power_supply_unit_(computer) dbr:Bridge_rectifier dbr:Electric_power_transmission dbr:AC_power dbr:SI dbr:Induction_motor dbr:Physical_quantity dbr:Electrical_substation dbr:Inductor dbr:Volt-ampere_reactive dbr:Eddy_currents n5:Lagging-Leading.jpg dbr:Buck_converter dbr:STATCOM dbr:Sine_wave dbr:Solenoid dbr:Welding dbr:Steel_mill dbr:Wattmeter dbr:Trigonometric_functions dbr:Valley-fill_circuit dbr:Voltage dbr:Electric_power_grid dbr:Real_power dbr:Switched-mode_power_supply dbr:Polyphase_system dbr:IEC_EN_61000-3-2 dbr:Utility_frequency dbr:Delta-wye_transformer dbr:Electrical_ballast n5:Blindleistungskompensation.svg dbr:Electrical_engineering dbr:Buck-boost_converter dbr:Vienna_rectifier dbr:Electrical_load dbr:Electrical_network dbr:Reactive_power dbr:Mains_electricity dbr:Synchronous_condenser dbr:Overvoltage dbc:Electrical_parameters dbr:Dimensionless_number dbr:Apparent_power dbr:Total_harmonic_distortion dbr:Linear
dbo:wikiPageExternalLink
n26:POWERFAC.pdf
owl:sameAs
dbpedia-bg:Фактор_на_мощността dbpedia-ru:Коэффициент_мощности dbpedia-sr:Фактор_снаге dbpedia-fi:Tehokerroin dbpedia-ka:სიმძლავრის_კოეფიციენტი dbpedia-sk:Účinník dbpedia-gl:Factor_de_potencia dbpedia-pt:Fator_de_potência n22:Faktor_daya n23:शक्ति_गुणांक dbpedia-pl:Współczynnik_mocy dbpedia-uk:Коефіцієнт_потужності dbpedia-tr:Güç_faktörü n29:ਪਾਵਰ_ਫ਼ੈਕਟਰ wikidata:Q750454 dbpedia-ro:Factor_de_putere dbpedia-zh:功率因数 dbpedia-vi:Hệ_số_công_suất yago-res:Power_factor dbpedia-ja:力率 dbpedia-it:Fattore_di_potenza n39:4167276-8 dbpedia-ar:معامل_القدرة dbpedia-eo:Faktoro_de_povumo dbpedia-ko:역률 dbpedia-fa:ضریب_توان freebase:m.0bdwm dbpedia-nl:Arbeidsfactor dbpedia-simple:Power_factor n48:Jaudas_koeficients dbpedia-es:Factor_de_potencia dbpedia-he:מקדם_הספק dbpedia-pnb:پاور_فیکٹر n52:পাওয়ার_ফ্যাক্টর dbpedia-et:Võimsustegur n54:ပါဝါညွှန်းကိန်း dbpedia-id:Faktor_daya_listrik dbpedia-cs:Účiník dbpedia-fr:Facteur_de_puissance dbpedia-ca:Factor_de_potència dbpedia-de:Leistungsfaktor dbpedia-lmo:Fator_de_potenza dbpedia-ms:Faktor_kuasa n62:4uXuB
dbp:wikiPageUsesTemplate
dbt:Main dbt:Reflist dbt:Mvar dbt:= dbt:Short_description dbt:For dbt:Citation dbt:Electricity_delivery dbt:Authority_control
dbo:thumbnail
n17:Power_Factor_General_Case.svg?width=300
dbo:abstract
功率因数(英語:power factor,縮寫:PF)又称功率因子,是交流電力系統中特有的物理量,是一負載所消耗的与其视在功率的比值,是0到1之間的無因次量。 有功功率代表一電路在特定時間作功的能力,视在功率是電壓和電流有效值的乘積。純電阻負載的视在功率等於有功功率,其功率因數為1。若負載是由電感、電容及電阻組成的線性負載,能量可能會在負載端及電源端往復流動,使得有功功率下降。若負載中有電感、電容及電阻以外的元件(非線性負載),會使得輸入電流的波形扭曲,也會使视在功率大於有功功率,這二種情形對應的功率因数會小於1。功率因数在一定程度上反映了发电机容量得以利用的比例,是合理用电的重要指标。 電力系統中,若一負載的功率因數較低,負載要產生相同功率輸出時所需要的電流就會提高。當電流提高時,電路系統的能量損失就會增加,而且電線及相關電力設備的容量也隨之增加。電力公司為了反映較大容量設備及浪費能量的成本,一般會對功率因數較低的工商業用戶以較高的電費費率來計算電費。 提高負載功率因數,使其接近1的技術稱為功率因數修正。低功率因數的線性負載(如感應馬達)可以藉由電感或電容組成的被動元件網路來提昇功因。非線性負載(如二極體)會使得輸入電流的波形扭曲,此情形可以由主動或被動的功率因數修正來抵消電流扭曲的影響,並且改善功因。功率因數修正設備可以位在中央變電站、分佈在電力系統中,或是放在耗能設備的內部。 功率因數和電效率二者是不同概念,一設備的效率是輸出功率相對於輸入功率的比值,和功因不同。一設備功率因數提昇後,設備本身的效率不一定會隨之提昇。但功率因數提昇後,視在功率及輸入電流會減小,因此供電系統的效率會提昇。 Коэффицие́нт мо́щности — безразмерная физическая величина, характеризующая потребителя переменного электрического тока с точки зрения наличия в нагрузке реактивной составляющей и мощности искажения (собирательное название — неактивная мощность). Следует отличать понятие «коэффициент мощности» от понятия «косинус фи», который равен косинусу сдвига фазы переменного тока, протекающего через нагрузку, относительно приложенного к ней напряжения. Второе понятие используют в случае синусоидальных тока и напряжения, и только в этом случае оба понятия эквивалентны. La faktoro de povumo estas karakteriza grando de elektra ricevilo. Ĝi egalas al la kvociento de la aktiva povumo transdonita al la ricevilo per la ŝajna povumo. La valoro de estas ĉiam inter 0 kaj 1. Se la kurento kaj la tensio estas sinusaj funkcioj de la tempo, la faktoro de povumo egalas al la kosinuso de la inter la kurento kaj la tensio. En enginyeria elèctrica, el factor de potència d'un sistema de potència elèctric de corrent altern es defineix com la ràtio entre la potència real i la potència aparent. És un paràmetre sense dimensions i el seu interval va de -1 A +1. El seu símbol és FP o també cos φ. Les càrregues resistives pures tenen un FP=1, en canvi les càrregues inductives pures (inductives o capacitives) tenen un FP=0. Коефіціє́нт поту́жності — безрозмірна фізична величина, що означує споживача змінного електричного струму з точки зору наявності в навантаженні реактивної складової. Коефіцієнт потужності показує, наскільки зсувається по фазі змінний струм, що протікає крізь навантаження, щодо прикладеної до нього напруги. Чисельно коефіцієнт потужності дорівнює косинусу цього фазового зсуву. In electrical engineering, the power factor of an AC power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. Real power is the average of the instantaneous product of voltage and current and represents the capacity of the electricity for performing work. Apparent power is the product of RMS current and voltage. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power may be greater than the real power, so more current flows in the circuit than would be required to transfer real power alone. A power factor magnitude of less than one indicates the voltage and current are not in phase, reducing the average product of the two. A negative power factor occurs when the device (which is normally the load) generates real power, which then flows back towards the source. In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor. Power-factor correction increases the power factor of a load, improving efficiency for the distribution system to which it is attached. Linear loads with a low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment. Le facteur de puissance est une caractéristique d'un récepteur électrique qui rend compte de son efficacité pour consommer de la puissance lorsqu'il est traversé par un courant. Pour un dipôle électrique alimenté en régime de courant variable au cours du temps (sinusoïdal ou non), il est égal à la puissance active P consommée par ce dipôle, divisée par le produit des valeurs efficaces du courant I et de la tension U (puissance apparente S). Il est toujours compris entre 0 et 1. En particulier, si le courant et la tension sont des fonctions sinusoïdales du temps, le facteur de puissance est égal au cosinus du déphasage entre le courant et la tension : Współczynnik mocy, – stosunek mocy czynnej do mocy pozornej, czyli stosunek mocy użytecznej do iloczynu napięcia i prądu. Powszechnie dziś stosowane w elektrotechnice pojęcie współczynnika mocy wprowadził pod koniec XIX wieku uczony polskiego pochodzenia Michał Doliwo-Dobrowolski pracujący wówczas w niemieckim koncernie AEG. W obwodach zasilanych napięciem sinusoidalnie zmiennym, a powodujących powstawanie prądu o przebiegach okresowych niesinusoidalnych, rozpatruje się bardzo często dwie składowe współczynnika mocy: * – składową związaną z przesunięciem fazowym między pierwszą harmoniczną prądu i napięciem; * – składowa związana z odkształceniem przebiegów prądu w stosunku do przebiegu napięcia. Całkowity współczynnik mocy wynosi wtedy: Moc czynną, bierną i pozorną można przedstawić graficznie w postaci trójkąta prostokątnego, zwanego trójkątem mocy. Z trójkąta tego wynika, że współczynnik mocy jest ilorazem mocy czynnej i pozornej: gdzie: – moc czynna, – moc pozorna (zespolona). Przy sinusoidalnym napięciu zasilania: Odbiorniki prądu przemiennego pobierają ze źródła moc pozorną a oddają na zewnątrz moc czynną w postaci energii cieplnej lub mechanicznej (wykonanej pracy). Als Leistungsfaktor (auch Wirkleistungsfaktor) wird in der elektrischen Wechselstromtechnik das Verhältnis vom Betrag der Wirkleistung zur Scheinleistung bezeichnet. Das Verhältnis wird in folgender Formel ausgedrückt: Der Leistungsfaktor kann zwischen 0 und 1 liegen: De arbeidsfactor of vermogensfactor is de verhouding tussen het werkelijke vermogen en het schijnbare vermogen in een wisselspanningsinstallatie. Het schijnbare vermogen is het product van de effectieve waarde van de elektrische spanning en van de elektrische stroomsterkte, en wordt uitgedrukt in de eenheid voltampère: Het werkelijke vermogen is de per tijdseenheid overgebrachte hoeveelheid energie, het deel van het vermogen dat daadwerkelijk wordt omgezet in warmte en arbeid. Het wordt uitgedrukt in watt (W): In een gelijkstroomcircuit is het werkelijke vermogen gelijk aan het product van de spanning en de stroomsterkte: In een wisselspanningcircuit met alleen een ohmse impedantie geldt een dergelijke relatie voor de effectieve waarden: Is er ook een niet-ohmse (reactieve) component van de impedantie, dan is er een faseverschil tussen spanning en stroom, of ook is er een afwijking als gevolg van het niet-sinusvormig karakter van spanning of stroom. Faktor daya listrik adalah nilai perbandingan antara dan . Rentang nilainya berkisar antara nol hingga satu. Faktor daya listrik dinyatakan dengan nilai cos φ. Pengamatan faktor daya listrik didasarkan pada jumlah arus listrik keseluruhan dalam suatu rangkaian listrik dan perbandingannya dengan jumlah arus yang terpakai. Pengambaran faktor daya dilakukan melalui sudut kosinus antara arus listrik dan tegangan listrik yang bekerja pada suatu . Faktor daya berguna untuk mengetahui tingkat efisiensi energi pada suatu beban listrik melalui nilai daya yang tidak terpakai dan terbuang sia-sia selama beban bekerja. In ingegneria elettrica, il fattore di potenza di un sistema elettrico a corrente alternata è il rapporto fra il modulo del vettore potenza attiva che alimenta un carico elettrico e il modulo del vettore potenza apparente che fluisce nel circuito. In un sistema con carichi lineari coincide con il coseno dell'angolo di sfasamento compreso tra i vettori tensione e corrente. È un numero adimensionale nell'intervallo chiuso tra -1 e 1. La potenza attiva è la capacità di un circuito di fornire un lavoro meccanico nell'unità di tempo t, ed è pari al prodotto scalare tra i vettori tensione (V) e corrente (I). La potenza apparente è il prodotto algebrico della tensione e della corrente circolanti in un circuito nell'istante t, preso in valore assoluto, in modulo, e rappresenta la potenza elettrica effettivamente circolante.In generale, la potenza apparente è maggiore della potenza attiva e la potenza attiva coincide con la potenza apparente solo quando il vettore corrente elettrica è concorde col vettore tensione elettrica, il che accade unicamente nel circuito ideale che contiene unicamente elementi dissipativi ideali detti resistori. Questo si verifica nei circuiti elettrici reali di piccola lunghezza in cui sono presenti solo resistenze elettriche, fatte le dovute approssimazioni, ovvero con piccoli scostamenti tra i valori di corrente attesi (teorici) e quelli misurati (reali) alle varie tensioni applicate. In tutti i casi reali differenti da questo, il vettore corrente che fluisce nel circuito non è in fase con il vettore tensione che l'ha generata per la presenza di fenomeni fisici riferibili alla capacità e all'induttanza. Va ricordato che la sollecitazione applicata al circuito, ovvero la tensione, è una grandezza alternata, rappresentabile come una generica grandezza sinusoidale, oscillante tra due valori, il massimo positivo e negativo, passante per zero, con frequenza costante, ovvero che si ripete con un periodo, un intervallo temporale, costante. Questo significa che le correnti generate sono variabili con la stessa frequenza della tensione (se nel circuito ci sono solo carichi lineari), ma a causa degli effetti induttivi e capacitivi i massimi, i minimi e gli zeri della corrente non sono contemporanei con i corrispettivi valori assunti dal vettore tensione in ciascun periodo: la corrente risulta "non in fase" ovvero sfasata in anticipo o in ritardo sulla tensione che l'ha generata. In altre parole, a causa del fatto che la potenza elettrica (e il flusso di energia) è immagazzinata in elementi del circuito reale quali induttori e condensatori elettrici, essa è restituita sfasata (in ritardo o in anticipo) nel tempo rispetto al vettore tensione del generatore: compaiono delle correnti non in fase con la tensione definite correnti reattive. In quasi tutti i circuiti reali, la corrente è in ritardo rispetto alla tensione e la potenza apparente risulta quasi sempre maggiore della potenza attiva. Importante considerare che nei circuiti reali la potenza attiva, quella che si trasforma tutta in potenza meccanica utile, è in realtà minore rispetto alla potenza apparente effettivamente circolante, dunque le dissipazioni del circuito (effetto termico per attrito del flusso di cariche attraverso il mezzo conduttore) proporzionali alla resistenza R (espressa dalla prima legge di Ohm) sono proporzionali alla potenza apparente: è utile ed opportuno ridurre queste perdite ovvero ridurre al minimo la componente della corrente non in fase con la tensione e questo si fa mediante l'aggiunta di un opportuno carico di rifasamento. In definitiva la grandezza elettrica fattore di potenza è utilizzata per dimensionare le due componenti attiva e reattiva in cui si può immaginare di scomporre il vettore potenza Apparente su un piano cartesiano ovvero in termini di seno e coseno, e si pone: con φ è indicato l'angolo di sfasamento, compreso tra il vettore tensione (V) e il vettore corrente (I). Per convenzione (coerente con i fenomeni fisici di capacità ed induttanza) si pone la tensione sull'asse x, la corrente reattiva capacitiva sull'asse positivo delle y e la corrente reattiva induttiva sull'asse negativo delle y.Ipotizzando per convenzione il verso antiorario di rotazione dei vettori sull'asse x, la corrente reattiva capacitiva è in anticipo rispetto alla tensione quindi la corrente reattiva induttiva in ritardo, con angolo di sfasamento φ = ± 90° = ± π/2 . Il valore negativo del fattore di potenza si ha quando il dispositivo definito carico, ovvero utenza, genera potenza. In questo caso la potenza fluisce dal circuito alla sorgente, al generatore, e il circuito stesso è considerato un generatore di energia. Se il circuito contiene uno o più carichi non-lineari (generalmente circuiti elettronici) si osserva anche una distorsione della forma d'onda della corrente ovvero una variazione della frequenza: alla frequenza generata dalla tensione, definita frequenza fondamentale (ad esempio 50 Hz in Europa) si aggiungono correnti con frequenze multiple della fondamentale dette di armonica superiore (ad esempio di terza armonica: 150 Hz, di quinta armonica: 250 Hz, di settima armonica: 350 Hz e così via). Se define factor de potencia, f.d.p., de un circuito de corriente alterna, potencia activa, P, y la potencia aparente, S.​Da una medida de la capacidad de una carga de absorber potencia activa. Por esta razón, f.d.p = 1 en cargas puramente resistivas. 力率(りきりつ、Power factor)は、交流電力の効率に関して定義された値であり、皮相電力に対する有効電力の割合である。料金計算などの電力の管理では、パーセントで表される。 O fator de potência (FP) é uma relação entre potência ativa e potência reativa por consequência energia ativa e reativa. Ele pode ser usado para indicar se a proporção entre potência reativa e ativa está adequada. O fator de potência de um sistema elétrico qualquer, que está operando em corrente alternada (CA), é definido pela razão da potência real ou potência ativa pela potência total ou potência aparente. Um FP alto indica uma boa eficiência quanto ao uso de energia, significa dizer que grande parte da energia drenada é transformada em trabalho, inversamente a isso um fator de potência baixo indica que você não está aproveitando plenamente a energia drenada (entende-se por "energia drenada" a energia que você compra da concessionaria). 전기에는 직류와 교류가 존재하는데, 역률(영어: power factor)은 교류와 관계된다. 왜냐하면, 직류에서는 전압과 전류의 곱으로 전력이 되는데, 그 공식은 아래와 같이 나타낼 수 있다. P = 전력, V = 전압, I = 전류 직류에서는 위상이라는 개념이 없다. 하지만, 교류에서는 위상이 존재하며, 교류회로에서 역률은 (Active Power [단위 : W])과 (Apparent Power [단위 : VA])의 비를 말하는데, 이를 간단히 풀어서 해석하면, “전기설비에 걸리는 전압과 전류가 얼마나 효율적으로 일을 잘 하고 있는가?”로 나타내는 지표로도 활용된다. 역률은 유효전력을 피상전력(외관상의 전력)으로 나눈값이며, 교류 회로에서 전류와 전압의 위상차를 코사인 값(cosθ)으로 나타낸다. 직류에서는 전압과 전류만 곱하면 그것이 전력이었으나, 교류는 전압과 전류의 실효값을 곱한 피상전력이라는 것에 역률을 곱하여야 비로소 전력이 된다. 왜냐하면 직류처럼 일정한 흐름이 아닌, 정현파의 형태를 그리며 계속 지속적으로 변하기 때문이다. 즉, 직류처럼 일정한 값이 아닌, 계속 지속적으로 변하는 값이기 때문에 위상이 반드시 일치하지는 않는 것이다. 여기서 피상전력은 전압(V)과 전류(I)의 곱 (VI) 이므로, 피상전력의 공식은 아래와 같이 나타낼 수 있다. 여기서 AP는 유효전력 (Active Power) / RP는 (Reactive Power)을 말한다. 유효전력은 다음과 같이 나타낼 수 있다. (단, 위상각) 무효전력은 다음과 같이 나타낼 수 있다. (단, 위상각) 역률을 구하려면 유효전력을 피상전력으로 나누어야 하며, 그 수식은 아래와 같이 나타낼 수 있다. 역률은 위와 같이 나타낼 수 있으며, 보통 역률은 최대 1로 표기된다. 표시방식은 보통 "EX1) 0.90 ~ 0.95" / "EX2) 0.76 => 76%" 이렇게 표시된다. 역률이 1 즉, 100% 라는 얘기는 무효전력 아예 존재하지 않다는 것임을 의미하며, 이때 유효전력은 피상전력과 같아지게 된다. 우리가 한전에서 전기요금 명세서를 받아보면, 거기에는 주거용(가정용)역률 90%[0.9]로 감안하여 전기요금에 반영이 되어있는데, 이는 가정집에서는 세탁기, 냉장고 등 전동기(코일 성분)로 동작을 시키기 때문에 주거용(가정용)역률은 100%가 될 수 없다. 시퀀스 회로도로 보면 알 수 있겠지만, 전동기로 기동이 되는 것은 거의 코일이 포함되어 있기 때문에 역률이 100%로 맞춰지지 못한다. 전압과 전류의 위상차이는 전력을 효율적으로 사용하지 못하는 무효전력을 발생시키고 이는 역률에 관계된다. 실제 수용가 측면에서는 초기 투자비의 과다와 실제 부하사용량에 따라 역률제어 실행 시 필요한 역률조정소자의 용량이 달라지기 때문에 건축전기설비설계 시 역률개선을 위한 역률제어반을 설치하지 않고 부하운용을 먼저 한 후, 역률제어반을 설치하게 되는데 이는 나중에 설치하게 되면 제한된 전기실의 공간으로 인하여 설치하기가 어려워지는 상황이 자주 발생됨. 저항(R)만 존재할 때, 회로의 역률은 전압과 전류의 위상이 없기 때문에 역률은 1로 나타낼 수 있다. 코일(L)만 존재할 때, 전압과 전류의 관계식은 으로 나타낼 수 있으며, 이는 전압을 기준으로 할 때 전류는 90도가 늦어져 위상이 90도 차이가 나게 되어, 역률은 0이 된다. 이러한 과정에 의하여 역률은 0이 되어, 전류는 전압보다 위상이 90도 늦지게 됨. 정전용량(C)만 존재할 때, 전압과 전류의 관계식은 으로 나타낼 수 있으며, 이는 전압을 기준으로 할 때 전류는 90도가 빨라져 위상이 90도 차이가 나게 되어, 코일만의 회로와 마찬가지로 역률은 0이 된다. Účiník je kosinus vzájemného fázového posuvu mezi proudem a napětím elektrického obvodu s harmonickými průběhy střídavých proudů a napětí či periodickými průběhy o jednotlivých harmonických složkách proudů a napětí. Účiník je poměrem činného a zdánlivého elektrického výkonu v obvodu střídavého proudu a napětí, vyjadřuje, jak velkou část zdánlivého výkonu přeměňuje obvod na činný výkon, tj. na součet užitečného výkonu a ztrát. Hodnota účiníku se pohybuje od nuly do jedné, při účiníku rovném jedné je zdánlivý výkon roven činnému výkonu (fázový posuv je nulový). Při nulovém účiníku je zdánlivý výkon roven jalovému výkonu, zátěž je buď čistě induktivní (fázový posuv je , tj. proud se zpožďuje za napětím) nebo čistě kapacitní (fázový posuv je , tj. napětí se zpožďuje za proudem). Hodnota účiníku menší než jedna způsobuje nežádoucí zvýšené ztráty energie přenášené vedením od zdroje ke spotřebiči. Značka: Jednotka SI: - معامل القدرة (Power Factor) هو النسبة بين إلى ، وهو مساوِ لجيب تمام زاوية الطور (cos_phi) - والتي هي فرق زاويتي الجهد والتيار. لذا فهو قيمة عددية ليس لها وحدة قياس تتراوح من الصفر إلى الواحد، في محطات القدرة يحبذ ويتم السعي إلى أن يكون معامل القدرة أكبر ما يمكن حيث أنه بزيادة درجة معامل القدرة يزداد مقدارالقدرة الفعالة وتنخفض القيمة أو وتتراوح قيم معاملات القدرة في محطات القدرة التي تعتمد نظام التيار المتردد الأحمال الكهربائية تقع في إحدى التصنيفات التالية: * مقاوِم Resistive * حثي Inductive * سعوي Capacitive والأحمال الكهربائية الأكثر شيوعاً هي الأحمال الحثية ومثال عليها: المحولات الكهربائية ومحركات التيار المستمر الحثية. وجميع هذه الأحمال (الحثية) تحتاج إلى نوعين من القدرة الكهربائية لكي تعمل: القدرة الفعّآلة أو القدرة الحقيقية Active Power or Real Power - KWالقدرة غير الفعّآلة Reactive Power - KVARالقدرة الفعّآلة هي القدرة المفيدة في الشبكة الكهربائية في حين أن القدرة غير الفعالة لا دور لها سوى توليد المجال المغناطيسي اللازم لعمل الأحمال الحثية. وفي جميع الأحوال، على شركات تزويد الطاقة الكهربائية تزويد التيار إلى أحمال المستهلكين بغض النظر أكانت مقاومية، سعوية أو حثية. وهذا التيار بلا شك، سيولّد طاقة مهدورة في خطوط النقل الكهربائي بحسب العلاقةمعامل القدرة الكهربائية يعني تزويد طاقة ظاهرة أكثر من الطاقة الفعالة وتدني معامل القدرة الكهربائية يؤدي إلى زيادة في توليد التيار للتعويض مما يؤدي إلى خسائر الطاقة
gold:hypernym
dbr:Number
prov:wasDerivedFrom
wikipedia-en:Power_factor?oldid=1124211251&ns=0
dbo:wikiPageLength
46539
foaf:isPrimaryTopicOf
wikipedia-en:Power_factor
Subject Item
dbr:Power_factor_correction
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:80_Plus
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Active_rectification
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Three-phase_electric_power
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Three_Gorges_Dam
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Watt
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:West_Burton_power_stations
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Wind_power
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Dissipation_factor
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Leading_and_lagging_current
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Leakage_inductance
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Liquid_rheostat
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Load_bank
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Load_factor_(electrical)
owl:differentFrom
dbr:Power_factor
Subject Item
dbr:Current_transformer
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:FS_Class_E.470
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Central_Organisation_for_Railway_Electrification
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Dielectric_barrier_discharge
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Fluorescent_lamp
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Glossary_of_fuel_cell_terms
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Glow_switch_starter
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Islanding
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Kill_A_Watt
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Magnetic_core
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Power_conditioner
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Static_VAR_compensator
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Synchronous_condenser
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Single-wire_earth_return
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Power_supply
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Register-transfer_level
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:APFC
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:HVDC_Inter-Island
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Transverter
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Wind_turbine_design
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Smith–Putnam_wind_turbine
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:AC_motor
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:AC_power
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:John_Ambrose_Fleming
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Kilowatt-hour
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Blocked_rotor_test
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Zobel_network
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Direct_torque_control
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Solar_power_in_India
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Film_capacitor
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Green_computing
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Grid-tie_inverter
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Grid_code
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Grow_light
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Warsaw_rectifier
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Incandescent_light_bulb
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Kálmán_Kandó
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Capability_curve
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Capacitive_power_supply
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Capacitor_types
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Wreck_Cove_Hydroelectric_System
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Motor_control_center
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Static_synchronous_compensator
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Switched-mode_power_supply
rdfs:seeAlso
dbr:Power_factor
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Scott-T_transformer
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Uninterruptible_power_supply
rdfs:seeAlso
dbr:Power_factor
Subject Item
dbr:Volt-ampere
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Wife_acceptance_factor
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Distortion_power_factor
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:IEC_61000-3-2
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Wattmeter
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Flexible_AC_transmission_system
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Open-circuit_test
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Passive_PFC
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Outline_of_electronics
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Outline_of_energy
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Synchronous_motor
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:UNIVAC_1105
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Voltage_optimisation
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Voltage_control_and_reactive_power_management
dbo:wikiPageWikiLink
dbr:Power_factor
Subject Item
dbr:Capacitive_load
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Eli_the_iceman
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Power_Factor
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Power_Factor_Correction_Unit
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Displacement_power_factor
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Inductive_load
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Active_PFC
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Active_power_factor_correction
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Lagging_current
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Lagging_load
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Leading_current
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Leading_load
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Power_Factor_Correction
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
dbr:Power_factor_correction_unit
dbo:wikiPageWikiLink
dbr:Power_factor
dbo:wikiPageRedirects
dbr:Power_factor
Subject Item
wikipedia-en:Power_factor
foaf:primaryTopic
dbr:Power_factor