dbo:abstract
|
- Das Twyman-Green-Interferometer (benannt nach und ) ist ein Interferometer, das heißt ein , das zur Charakterisierung und Prüfung von optischen Komponenten, wie Linsen oder Prismen, eingesetzt wird. (de)
- A Twyman–Green interferometer is a variant of the Michelson interferometer principally used to test optical components. It was introduced in 1916 by Frank Twyman and Arthur Green. Fig. 1 illustrates a Twyman–Green interferometer set up to test a lens. Light from a laser is expanded by a diverging lens (not shown), then is collimated into a parallel beam. A convex spherical mirror is positioned so that its center of curvature coincides with the focus of the lens being tested. The emergent beam is recorded by an imaging system for analysis. The fixed mirror in the Michelson interferometer is rotatable in the Twyman–Green interferometer, and while the light source is usually an extended source (although it can also be a laser) in a Michelson interferometer, the light source is always a point-like source in the Twyman–Green interferometer. The rotation of one mirror results in straight fringes appearing in the interference pattern, a fringing which is used to test the quality of optical components by observing changes in the fringe pattern when the component is placed in one arm of the interferometer. (en)
- Interferometr Twymana-Greena - przyrząd optyczny podobny do interferometru Michelsona. Służy do badania elementów optycznych (np. pryzmatów, soczewek) oraz całych układów optycznych (np. obiektywów). Zbudowany jest, podobnie jak interferometr Michelsona, z dwóch ramion. Na jednym z ramion umieszcza się badany element. Na drugim ramieniu znajduje się lustro odbijające porównawczą wiązkę światła. Wszelkie niejednorodności i niedoskonałości badanego elementu powodują powstanie prążków interferencyjnych uzyskanych z superpozycji wiązki porównawczej z wiązką, która przeszła przez element. Prążki te, w zależności od charakteru niedoskonałości elementu, mogą być liniowe, lub mogą przypominać poziomice na mapach. Jeżeli badany element optyczny pozbawiony jest jakichkolwiek niedoskonałości, wówczas obie wiązki światła są dokładnie zgodne w fazie i obraz jest jednolity - bez jakichkolwiek wzmocnień i osłabień. (pl)
|
dbo:thumbnail
| |
dbo:wikiPageID
| |
dbo:wikiPageLength
|
- 2146 (xsd:nonNegativeInteger)
|
dbo:wikiPageRevisionID
| |
dbo:wikiPageWikiLink
| |
dbp:wikiPageUsesTemplate
| |
dcterms:subject
| |
gold:hypernym
| |
rdf:type
| |
rdfs:comment
|
- Das Twyman-Green-Interferometer (benannt nach und ) ist ein Interferometer, das heißt ein , das zur Charakterisierung und Prüfung von optischen Komponenten, wie Linsen oder Prismen, eingesetzt wird. (de)
- A Twyman–Green interferometer is a variant of the Michelson interferometer principally used to test optical components. It was introduced in 1916 by Frank Twyman and Arthur Green. Fig. 1 illustrates a Twyman–Green interferometer set up to test a lens. Light from a laser is expanded by a diverging lens (not shown), then is collimated into a parallel beam. A convex spherical mirror is positioned so that its center of curvature coincides with the focus of the lens being tested. The emergent beam is recorded by an imaging system for analysis. (en)
- Interferometr Twymana-Greena - przyrząd optyczny podobny do interferometru Michelsona. Służy do badania elementów optycznych (np. pryzmatów, soczewek) oraz całych układów optycznych (np. obiektywów). Zbudowany jest, podobnie jak interferometr Michelsona, z dwóch ramion. Na jednym z ramion umieszcza się badany element. Na drugim ramieniu znajduje się lustro odbijające porównawczą wiązkę światła. Wszelkie niejednorodności i niedoskonałości badanego elementu powodują powstanie prążków interferencyjnych uzyskanych z superpozycji wiązki porównawczej z wiązką, która przeszła przez element. Prążki te, w zależności od charakteru niedoskonałości elementu, mogą być liniowe, lub mogą przypominać poziomice na mapach. Jeżeli badany element optyczny pozbawiony jest jakichkolwiek niedoskonałości, wówczas (pl)
|
rdfs:label
|
- Twyman-Green-Interferometer (de)
- Interferometr Twymana-Greena (pl)
- Twyman–Green interferometer (en)
|
owl:sameAs
| |
prov:wasDerivedFrom
| |
foaf:depiction
| |
foaf:isPrimaryTopicOf
| |
is dbo:wikiPageDisambiguates
of | |
is dbo:wikiPageRedirects
of | |
is dbo:wikiPageWikiLink
of | |
is dbp:significantDesign
of | |
is foaf:primaryTopic
of | |