An Entity of Type: Thing, from Named Graph: http://dbpedia.org, within Data Space: dbpedia.org

Pure-tone audiometry is the main hearing test used to identify hearing threshold levels of an individual, enabling determination of the degree, type and configuration of a hearing loss and thus providing a basis for diagnosis and management. Pure-tone audiometry is a subjective, behavioural measurement of a hearing threshold, as it relies on patient responses to pure tone stimuli. Therefore, pure-tone audiometry is only used on adults and children old enough to cooperate with the test procedure. As with most clinical tests, standardized calibration of the test environment, the equipment and the stimuli is needed before testing proceeds (in reference to ISO, ANSI, or other standardization body). Pure-tone audiometry only measures audibility thresholds, rather than other aspects of hearing s

Property Value
dbo:abstract
  • قِياس سمع النّغْمة النَّقِية (بالإنجليزية:pure tone audiometry)(باختصار PTA) هو اختبار السمع الرئيسي المستخدم لتحديد مستويات عتبة السمع، مما يتيح تحديد درجة ونوع فقدان السمع وبالتالي توفير أساس للتشخيص والإدارة. بمعنى آخر، هو اختبار وقياس سلوكي ذاتي لعتبة السمع، لأنه يعتمد على استجابات المريض لمنبهات النغمة النقية، وهو مصمم لقياس شدة وتوازن السمع الأحادي الجانب أو الثنائي الجانب بهدف تشخيص فقدان السمع لدى الشخص. ولذلك، يتم استخدامه فقط على الأشخاص البالغين والأطفال الناضجين بما يكفي للتعاون مع إجراءات الاختبار. يتم تسجيل نتائج الاختبار على شكل مخطط للسمع. تُظهر النتائج عتبة النغمة النقية للشخص (PTT)، وهي الصوت الأكثر هدوءًا الذي يمكن سماعه على الأقل بنسبة 50 بالمائة من الوقت. عند الانتهاء من هذا الاختبار، سيكون أخصائي السمع قادرًا على معرفة درجة فقدان السمع التي يعاني منها الشخص وما إذا كان ذلك يؤثر على إحدى الأذنين أم كليهما. عادةً ما يتم اختبار السمع الوظيفي (أو السمع المحيطي) لكل أذن على حدة، تحت سماعات معايرة سريريًا. يتم اختبار الترددات المختلفة (هرتز) بمستويات شدة مختلفة (ديسيبل). يمكن للأذن البشرية السليمة عادةً اكتشاف ما بين 20 و 20000 هرتز مع نطاق شدة صوتية من 0 إلى 120 ديسيبل. يمكن تمثيل مكونات صوت الكلام من 125-8000 هرتز حسب السماعة. ولذلك، يركز اختبار قياس النغمة النقية عادة على الترددات الممثلة في الأصوات البشرية من الذكور والإناث، وهي 250-8000 هرتز. يمكن أن يختلف عدد الترددات المختارة حسب عمر الشخص الذي تم اختباره، وسبب الاختبار، والوقت المخصص للاختبار. يشير متوسط النغمة النقية (PTA) إلى متوسط مستويات عتبة السمع عند مجموعة من الترددات المحددة: عادة 500 و 1000 و 2000 و 4000 هرتز. تعطي هذه القيمة فكرة عن مستوى السمع للفرد في كل أذن. نظرًا لأن أصوات الكلام يتم تمثيلها بشكل أكثر كثافة في الترددات المتوسطة، لا يتم تضمين الترددات الخارجية في حساب متوسط النغمة النقية PTA للسماح بمقارنات أكثر اتساقًا. إذا كان PTA أقل من 25 ديسيبل، فسيتم اعتبار السنه ضمن الحدود الطبيعية. في حال كان ال PTA 95 ديسيبل، سيتم النظر في جلسة أخرى. يجب أن تكون قيمة هذا المتوسط قريبة من عتبة استقبال الكلام (SRT) في حدود 5 ديسيبل وعتبة كشف الكلام (SDT) في حولي 6-8 ديسيبل.PTA مفيد أيضًا عند مقارنة إحدى الأذنين بالأخرى، لتحديد ما إذا كان الشخص يعاني من «سمع أفضل» في أحد الأذنين. (ar)
  • Pure-tone audiometry is the main hearing test used to identify hearing threshold levels of an individual, enabling determination of the degree, type and configuration of a hearing loss and thus providing a basis for diagnosis and management. Pure-tone audiometry is a subjective, behavioural measurement of a hearing threshold, as it relies on patient responses to pure tone stimuli. Therefore, pure-tone audiometry is only used on adults and children old enough to cooperate with the test procedure. As with most clinical tests, standardized calibration of the test environment, the equipment and the stimuli is needed before testing proceeds (in reference to ISO, ANSI, or other standardization body). Pure-tone audiometry only measures audibility thresholds, rather than other aspects of hearing such as sound localization and speech recognition. However, there are benefits to using pure-tone audiometry over other forms of hearing test, such as click auditory brainstem response (ABR). Pure-tone audiometry provides ear specific thresholds, and uses frequency specific pure tones to give place specific responses, so that the configuration of a hearing loss can be identified. As pure-tone audiometry uses both air and bone conduction audiometry, the type of loss can also be identified via the . Although pure-tone audiometry has many clinical benefits, it is not perfect at identifying all losses, such as ‘dead regions’ of the cochlea and neuropathies such as auditory processing disorder (APD). This raises the question of whether or not audiograms accurately predict someone's perceived degree of disability. (en)
  • Audiometria tonalna (ang. Pure Tone Audiometry, PTA) – jedna z najczęściej stosowanych metod subiektywnego badania słuchu. Jej głównym celem jest ocena progu słyszenia, pozwalająca określić rodzaj oraz stopień upośledzenia tego zmysłu. (pl)
dbo:thumbnail
dbo:wikiPageExternalLink
dbo:wikiPageID
  • 9519688 (xsd:integer)
dbo:wikiPageLength
  • 18480 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1074570676 (xsd:integer)
dbo:wikiPageWikiLink
dbp:caption
  • Diagram of the human ear (en)
dbp:emedicineSubj
  • article (en)
dbp:emedicineTopic
  • 1822962 (xsd:integer)
dbp:meshid
  • D001301 (en)
dbp:name
  • Pure tone audiometry (en)
dbp:wikiPageUsesTemplate
dcterms:subject
rdfs:comment
  • Audiometria tonalna (ang. Pure Tone Audiometry, PTA) – jedna z najczęściej stosowanych metod subiektywnego badania słuchu. Jej głównym celem jest ocena progu słyszenia, pozwalająca określić rodzaj oraz stopień upośledzenia tego zmysłu. (pl)
  • قِياس سمع النّغْمة النَّقِية (بالإنجليزية:pure tone audiometry)(باختصار PTA) هو اختبار السمع الرئيسي المستخدم لتحديد مستويات عتبة السمع، مما يتيح تحديد درجة ونوع فقدان السمع وبالتالي توفير أساس للتشخيص والإدارة. بمعنى آخر، هو اختبار وقياس سلوكي ذاتي لعتبة السمع، لأنه يعتمد على استجابات المريض لمنبهات النغمة النقية، وهو مصمم لقياس شدة وتوازن السمع الأحادي الجانب أو الثنائي الجانب بهدف تشخيص فقدان السمع لدى الشخص. ولذلك، يتم استخدامه فقط على الأشخاص البالغين والأطفال الناضجين بما يكفي للتعاون مع إجراءات الاختبار. (ar)
  • Pure-tone audiometry is the main hearing test used to identify hearing threshold levels of an individual, enabling determination of the degree, type and configuration of a hearing loss and thus providing a basis for diagnosis and management. Pure-tone audiometry is a subjective, behavioural measurement of a hearing threshold, as it relies on patient responses to pure tone stimuli. Therefore, pure-tone audiometry is only used on adults and children old enough to cooperate with the test procedure. As with most clinical tests, standardized calibration of the test environment, the equipment and the stimuli is needed before testing proceeds (in reference to ISO, ANSI, or other standardization body). Pure-tone audiometry only measures audibility thresholds, rather than other aspects of hearing s (en)
rdfs:label
  • قياس سمع النغمة النقية (ar)
  • Pure-tone audiometry (en)
  • Audiometria tonalna (pl)
owl:sameAs
prov:wasDerivedFrom
foaf:depiction
foaf:isPrimaryTopicOf
is dbo:wikiPageRedirects of
is dbo:wikiPageWikiLink of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License