An Entity of Type: Whole100003553, from Named Graph: http://dbpedia.org, within Data Space: dbpedia.org

The Murray loop bridge is a bridge circuit used for locating faults in underground or underwater cables. It has been used for more than 100 years but is being replaced by the more precise Time-domain reflectometer. One end of the faulted cable is connected through a pair of resistors to the voltage source. Also a null detector is connected. The other end of the cable is shorted. The bridge is brought to balance by changing the values of RB1 and RB2, which is achieved when: which is equivalent to: where L is the total length of the cable under test - a value proportional to Rg.

Property Value
dbo:abstract
  • The Murray loop bridge is a bridge circuit used for locating faults in underground or underwater cables. It has been used for more than 100 years but is being replaced by the more precise Time-domain reflectometer. One end of the faulted cable is connected through a pair of resistors to the voltage source. Also a null detector is connected. The other end of the cable is shorted. The bridge is brought to balance by changing the values of RB1 and RB2, which is achieved when: which is equivalent to: The value of resistance Rx is proportional the length Lx, thus the location of the fault can be calculated: where L is the total length of the cable under test - a value proportional to Rg. The method assumes a single fault exists, of low resistance compared with the undamaged cable insulation resistance, and that the cable conductors have uniform resistance per unit length. (en)
dbo:thumbnail
dbo:wikiPageID
  • 20294668 (xsd:integer)
dbo:wikiPageLength
  • 2621 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1105823233 (xsd:integer)
dbo:wikiPageWikiLink
dbp:wikiPageUsesTemplate
dcterms:subject
rdf:type
rdfs:comment
  • The Murray loop bridge is a bridge circuit used for locating faults in underground or underwater cables. It has been used for more than 100 years but is being replaced by the more precise Time-domain reflectometer. One end of the faulted cable is connected through a pair of resistors to the voltage source. Also a null detector is connected. The other end of the cable is shorted. The bridge is brought to balance by changing the values of RB1 and RB2, which is achieved when: which is equivalent to: where L is the total length of the cable under test - a value proportional to Rg. (en)
rdfs:label
  • Murray loop bridge (en)
owl:sameAs
prov:wasDerivedFrom
foaf:depiction
foaf:isPrimaryTopicOf
is dbo:wikiPageRedirects of
is dbo:wikiPageWikiLink of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License