The MECIF Protocol (Medical Computer Interface Protocol), is a rare communications protocol originally developed by Hewlett-Packard to allow external devices (e.g. computers) to communicate with certain Hewlett-Packard patient monitors. It is a client–server based protocol that uses a modified RS-232 cable to allow a client (e.g. a computer) to send commands to a server (e.g. patient monitor). The protocol can be used to retrieve vital data from patient monitors, such as ECG, blood pressure and heart-rate signals.

Property Value
dbo:abstract
  • The MECIF Protocol (Medical Computer Interface Protocol), is a rare communications protocol originally developed by Hewlett-Packard to allow external devices (e.g. computers) to communicate with certain Hewlett-Packard patient monitors. It is a client–server based protocol that uses a modified RS-232 cable to allow a client (e.g. a computer) to send commands to a server (e.g. patient monitor). The protocol can be used to retrieve vital data from patient monitors, such as ECG, blood pressure and heart-rate signals. Ownership of the protocol has changed hands many times and was most recently supported by Philips. Due to the complexity of the protocol, very few software applications currently support it. (en)
dbo:wikiPageExternalLink
dbo:wikiPageID
  • 25449801 (xsd:integer)
dbo:wikiPageLength
  • 1696 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1076574059 (xsd:integer)
dbo:wikiPageWikiLink
dbp:wikiPageUsesTemplate
dcterms:subject
gold:hypernym
rdf:type
rdfs:comment
  • The MECIF Protocol (Medical Computer Interface Protocol), is a rare communications protocol originally developed by Hewlett-Packard to allow external devices (e.g. computers) to communicate with certain Hewlett-Packard patient monitors. It is a client–server based protocol that uses a modified RS-232 cable to allow a client (e.g. a computer) to send commands to a server (e.g. patient monitor). The protocol can be used to retrieve vital data from patient monitors, such as ECG, blood pressure and heart-rate signals. (en)
rdfs:label
  • MECIF Protocol (en)
owl:sameAs
prov:wasDerivedFrom
foaf:isPrimaryTopicOf
is dbo:wikiPageRedirects of
is dbo:wikiPageWikiLink of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License