An Entity of Type: Thing, from Named Graph: http://dbpedia.org, within Data Space: dbpedia.org

The Likens-Nickerson apparatus is a piece of laboratory glassware devised by Sam T. Likens and Gail B. Nickerson for the detection of hop oil constituents in 1964. The apparatus performs a simultaneous steam distillation and extraction. The apparatus is typically constructed of borosilicate glass with the cold finger condenser and boiling flasks fitted with ground glass joints. It is typically used to isolate target organic compounds for further quantitative and or qualitative analysis using instrumental chemistry. However, it can also be used to isolate target compound(s) from an aqueous solution as a way of recovering valuable material.

Property Value
dbo:abstract
  • The Likens-Nickerson apparatus is a piece of laboratory glassware devised by Sam T. Likens and Gail B. Nickerson for the detection of hop oil constituents in 1964. The apparatus performs a simultaneous steam distillation and extraction. The apparatus is typically constructed of borosilicate glass with the cold finger condenser and boiling flasks fitted with ground glass joints. It is typically used to isolate target organic compounds for further quantitative and or qualitative analysis using instrumental chemistry. However, it can also be used to isolate target compound(s) from an aqueous solution as a way of recovering valuable material. (en)
dbo:thumbnail
dbo:wikiPageExternalLink
dbo:wikiPageID
  • 68395299 (xsd:integer)
dbo:wikiPageLength
  • 6043 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1051527194 (xsd:integer)
dbo:wikiPageWikiLink
dbp:wikiPageUsesTemplate
dcterms:subject
rdfs:comment
  • The Likens-Nickerson apparatus is a piece of laboratory glassware devised by Sam T. Likens and Gail B. Nickerson for the detection of hop oil constituents in 1964. The apparatus performs a simultaneous steam distillation and extraction. The apparatus is typically constructed of borosilicate glass with the cold finger condenser and boiling flasks fitted with ground glass joints. It is typically used to isolate target organic compounds for further quantitative and or qualitative analysis using instrumental chemistry. However, it can also be used to isolate target compound(s) from an aqueous solution as a way of recovering valuable material. (en)
rdfs:label
  • Likens-Nickerson Apparatus (en)
owl:sameAs
prov:wasDerivedFrom
foaf:depiction
foaf:isPrimaryTopicOf
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License