Life Cycle Climate Performance (LCCP) is an evolving method to evaluate the carbon footprint and global warming impact of heating, ventilation, air conditioning (AC), refrigeration systems, and potentially other applications such as thermal insulating foam. It is calculated as the sum of direct, indirect, and embodied greenhouse gas (GHG) emissions generated over the lifetime of the system “from cradle to grave,” i.e. from manufacture to disposal. Direct emissions include all climate forcing effects from the release of refrigerants into the atmosphere, including annual leakage and losses during service and disposal of the unit. Indirect emissions include the climate forcing effects of GHG emissions from the electricity powering the equipment. The embodied emissions include the climate forc

Property Value
dbo:abstract
  • LCCP (anglicky Life Cycle Climate Performance) je index charakterizující, jaký dopad na globální klima může mít určitý výrobek během své životnosti. Koncept LCCP se používá v oblasti chlazení a klimatizace a výrobkem jsou zde proto míněna jakákoliv zařízení stacionární i transportní, která obsahují chladivo (chladicí zařízení, klimatizační jednotky, tepelná čerpadla). LCCP je výsledkem postupného vývoje názorů na potenciální ovlivňování životního prostředí v důsledku provozu chladicích systémů. Po roce 1980 se odborníci zabývali hlavně ochranou ozonové vrstvy v souvislosti s úniky halogenovaných uhlovodíků do atmosféry. Chemické látky se z tohoto hlediska charakterizovaly pomocí ODP (Ozone Depletion Potential). O něco později se začíná prosazovat hypotéza o významném vlivu člověka na změny globálního klimatu. Jednotlivé skleníkové plyny se charakterizují s použitím různých koeficientů jako PGO (Potenciál globálního oteplování), HGWP (Halocarbon Global Warming Potential), TEWI (Total Equivalent Warming Impact), LCWI (Life Cycle Warming Impact), až se v roce 1999 zavedl parametr LCCP. Jednotlivé složky LCCP Při pokusech o výpočet LCCP se emise do atmosféry dělí v zásadě na dvě skupiny: emise přímé a nepřímé. Takové dělení bylo známé už z předchozího parametru TEWI: Význam použitých symbolů je na konci tohoto textu. První člen odpovídá přímým emisím a druhý člen , při výpočtu TEWI převažující a tedy mnohem významnější, odpovídá emisím nepřímým. Index LCCP má však ambice vyšší, a to zejména ve svém druhém členu popisujícím nepřímé emise. Zatímco TEWI hodnotí vybrané zařízení pouze po dobu jeho aktivní životnosti, o LCCP se říká, že z hlediska vlivu na životní prostředí charakterizuje daný výrobek „od kolébky až do hrobu“. Ve skutečnosti však LCCP jde ještě dál, totiž „před kolébku a za hrob“, protože zahrnuje i emise CO2 související s výrobou materiálů, komponent a chladiv pro následnou výrobu chladicího zařízení, jakož i emise CO2 související s recyklací materiálů včetně použitého chladiva po skončení jeho životnosti. Obecný výraz pro výpočet LCCP lze vyjádřit např. takto : LCCP [kg] vyjadřuje ekvivalentní množství CO2, tedy takové množství CO2, které by v atmosféře mělo podobný efekt, jako všechny skleníkové plyny vyprodukované během života daného zařízení. Hlavní potíž při výpočtech hodnot LCCP pro různá zařízení spočívá v tom, že do výpočtu vstupují desítky parametrů, které lze mnohdy odhadovat pouze s velkou mírou nejistoty. Demonstrovat to lze např. na parametru , který se mění od oblasti k oblasti (např. od 0 do 0,8 kg/kWh v závislosti na způsobu výroby elektrické energie). Přenosové soustavy různých regionů jsou dnes navíc propojeny, což dále komplikuje snahu o kvalifikovaný odhad . Používají se proto zprůměrované hodnoty, např. pro Evropskou unii se jako průměr uvádí kg/kWh, za celosvětový průměr se považuje hodnota kg/kWh a pro některé regiony USA se uvádějí hodnoty ještě o něco vyšší. V literatuře existují odhady středních hodnot i pro ostatní parametry vstupující do výpočtu LCCP a lze tam najít i přehled různých programů (LCCP Tools) usnadňujících poměrně komplikované výpočty LCCP. (cs)
  • Life Cycle Climate Performance (LCCP) is an evolving method to evaluate the carbon footprint and global warming impact of heating, ventilation, air conditioning (AC), refrigeration systems, and potentially other applications such as thermal insulating foam. It is calculated as the sum of direct, indirect, and embodied greenhouse gas (GHG) emissions generated over the lifetime of the system “from cradle to grave,” i.e. from manufacture to disposal. Direct emissions include all climate forcing effects from the release of refrigerants into the atmosphere, including annual leakage and losses during service and disposal of the unit. Indirect emissions include the climate forcing effects of GHG emissions from the electricity powering the equipment. The embodied emissions include the climate forcing effects of the manufacturing processes, transport, and installation for the refrigerant, materials, and equipment, and for recycle or other disposal of the product at end of its useful life. LCCP is more inclusive than previous metrics such as Total Equivalent Warming Impact (TEWI), which considers direct and indirect GHG emissions but overlooks embodied emissions, and Life Cycle Warming Impact (LCWI), which considers direct, indirect and refrigerant manufacturing emissions but overlooks appliance manufacturing, materials, transport installation and recycle. Enhanced and Localized Life Cycle Climate Performance (EL-LCCP) is the latest and most comprehensive carbon metric and takes into account: 1) real-world operating conditions, including the actual hour-by-hour carbon intensity of electricity generation, transmission, and distribution, which is degraded by high ambient temperature; 2) specific conditions of AC condensers located within urban heat islands and in locations with poor air circulation (mounted to close to buildings, clustered and stacked), as well of refrigerators and refrigerated display cases located against walls, inside cabinets, and other locations that compromise energy efficiency; 3) local climate conditions, such as higher ambient temperature at the location of the equipment than at the weather monitoring stations, which typically are located away from human influence. TEWI was developed by experts at Oak Ridge National Laboratory under contract from Allied Signal (now Honeywell) and was a step forward as a complement and enhancement of previous metrics like coefficient of performance (COP) and Seasonal Energy Efficiency Ratio (SEER), which consider energy use but not global warming potential (GWP) and emissions of refrigerants. (en)
dbo:wikiPageID
  • 63282018 (xsd:integer)
dbo:wikiPageLength
  • 10257 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1045084666 (xsd:integer)
dbo:wikiPageWikiLink
dbp:wikiPageUsesTemplate
dcterms:subject
rdfs:comment
  • LCCP (anglicky Life Cycle Climate Performance) je index charakterizující, jaký dopad na globální klima může mít určitý výrobek během své životnosti. Koncept LCCP se používá v oblasti chlazení a klimatizace a výrobkem jsou zde proto míněna jakákoliv zařízení stacionární i transportní, která obsahují chladivo (chladicí zařízení, klimatizační jednotky, tepelná čerpadla). Jednotlivé složky LCCP Při pokusech o výpočet LCCP se emise do atmosféry dělí v zásadě na dvě skupiny: emise přímé a nepřímé. Takové dělení bylo známé už z předchozího parametru TEWI: (cs)
  • Life Cycle Climate Performance (LCCP) is an evolving method to evaluate the carbon footprint and global warming impact of heating, ventilation, air conditioning (AC), refrigeration systems, and potentially other applications such as thermal insulating foam. It is calculated as the sum of direct, indirect, and embodied greenhouse gas (GHG) emissions generated over the lifetime of the system “from cradle to grave,” i.e. from manufacture to disposal. Direct emissions include all climate forcing effects from the release of refrigerants into the atmosphere, including annual leakage and losses during service and disposal of the unit. Indirect emissions include the climate forcing effects of GHG emissions from the electricity powering the equipment. The embodied emissions include the climate forc (en)
rdfs:label
  • LCCP (chlazení a klimatizace) (cs)
  • Life Cycle Climate Performance (en)
owl:sameAs
prov:wasDerivedFrom
foaf:isPrimaryTopicOf
is dbo:wikiPageRedirects of
is dbo:wikiPageWikiLink of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License