About: Gradient echo

An Entity of Type: Thing, from Named Graph: http://dbpedia.org, within Data Space: dbpedia.org

Gradient echo is a magnetic resonance imaging (MRI) sequence that has wide variety of applications, from magnetic resonance angiography to perfusion MRI and diffusion MRI. Rapid imaging acquisition allows it to be applied to 2D and 3D MRI imaging. Gradient echo uses magnetic gradients to generate a signal, instead of using 180 degrees radiofrequency pulse like spin echo; thus leading to faster image acquisition time.

Property Value
dbo:abstract
  • Gradient echo is a magnetic resonance imaging (MRI) sequence that has wide variety of applications, from magnetic resonance angiography to perfusion MRI and diffusion MRI. Rapid imaging acquisition allows it to be applied to 2D and 3D MRI imaging. Gradient echo uses magnetic gradients to generate a signal, instead of using 180 degrees radiofrequency pulse like spin echo; thus leading to faster image acquisition time. (en)
  • La sequenza gradient echo è una sequenza di eccitazione per l'imaging a risonanza magnetica alla base di molte importanti sequenze derivate quali l'echo-planar imaging o le sequenze in stato stazionario . Essa permette di ottenere tempi di ripetizione TR molto brevi, e quindi acquisire immagini in poco tempo. (it)
  • グラジェントエコー法(ぐらじえんとえこーほう、GRE,GE:gradient echo) スピンの磁化を観測するための一方法。スピンエコー法における180°パルスに変えて、磁場勾配を反転(傾斜磁場反転)させることによりエコー信号を発生させる。TR、TEの短縮が可能となり、高速スキャンや3Dボリュームスキャンに応用されている。しかし、リフェーズに180°パルスを用いないので、静磁場の不均一性の影響を受けやすく、スピンエコー法よりも画質が劣化する。エコー信号収集後に残存横磁化成分を強制的に消滅させるためにスポイラーパルスを付加するタイプ(FLASHやSPGRなど)と完全なSSFP(定常自由歳差)状態を意図したタイプ(FISP、GRASSなど)に分けることができる。TR、TE、フリップ角の調整で画像のコントラストを変化させる。 (ja)
dbo:wikiPageID
  • 56277564 (xsd:integer)
dbo:wikiPageLength
  • 9518 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1121066721 (xsd:integer)
dbo:wikiPageWikiLink
dbp:b
  • 2 (xsd:integer)
dbp:p
  • * (en)
dbp:wikiPageUsesTemplate
dcterms:subject
rdfs:comment
  • Gradient echo is a magnetic resonance imaging (MRI) sequence that has wide variety of applications, from magnetic resonance angiography to perfusion MRI and diffusion MRI. Rapid imaging acquisition allows it to be applied to 2D and 3D MRI imaging. Gradient echo uses magnetic gradients to generate a signal, instead of using 180 degrees radiofrequency pulse like spin echo; thus leading to faster image acquisition time. (en)
  • La sequenza gradient echo è una sequenza di eccitazione per l'imaging a risonanza magnetica alla base di molte importanti sequenze derivate quali l'echo-planar imaging o le sequenze in stato stazionario . Essa permette di ottenere tempi di ripetizione TR molto brevi, e quindi acquisire immagini in poco tempo. (it)
  • グラジェントエコー法(ぐらじえんとえこーほう、GRE,GE:gradient echo) スピンの磁化を観測するための一方法。スピンエコー法における180°パルスに変えて、磁場勾配を反転(傾斜磁場反転)させることによりエコー信号を発生させる。TR、TEの短縮が可能となり、高速スキャンや3Dボリュームスキャンに応用されている。しかし、リフェーズに180°パルスを用いないので、静磁場の不均一性の影響を受けやすく、スピンエコー法よりも画質が劣化する。エコー信号収集後に残存横磁化成分を強制的に消滅させるためにスポイラーパルスを付加するタイプ(FLASHやSPGRなど)と完全なSSFP(定常自由歳差)状態を意図したタイプ(FISP、GRASSなど)に分けることができる。TR、TE、フリップ角の調整で画像のコントラストを変化させる。 (ja)
rdfs:label
  • Gradient echo (en)
  • Gradient echo (it)
  • グラジェントエコー法 (ja)
owl:sameAs
prov:wasDerivedFrom
foaf:isPrimaryTopicOf
is dbo:wikiPageWikiLink of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License