An Entity of Type: cricketer, from Named Graph: http://dbpedia.org, within Data Space: dbpedia.org

An electrical isolation test is a Direct current (DC) or Alternating current (AC) resistance test that is performed between sub-circuit common and subsystem chassis to verify that a specified level of isolation resistance is met. Isolation testing may also be conducted between one or more electrical circuits of the same subsystem. The test often reveals problems that occurred during assembly, such as defective/wrong component, improper component placement/orientation and wire insulation or insulator defects that may cause inadvertent shorting or grounding to chassis, in turn, compromising electrical circuit quality and product safety.

Property Value
dbo:abstract
  • اختبار العزل الكهربي هو اختبار مقاومة التيار المستمر (DC).ويهدف الاختبار إلى التحقق من: * وصول النظام إلى المستوي المطلوب من العزل. * اكتشاف المشاكل التي حدثت أثناء عملية التوصيل والتركيب. * اكتشاف عيوب العازل، التي تؤدي إلى تقليل المقاومة. * التأكد من جودة وكفاءة الدائرة الكهربية، وسلامة النظام. (ar)
  • Eine Isolationsmessung ist eine Messung des Isolationswiderstands und dient der Prüfung der Isolation, um deren Sicherheit oder Fehlerfreiheit zu erkennen. Der Nachweis des Isolationswiderstandes durch Messungen ist gesetzlich für elektrische Betriebsmittel in vielen Zusammenhängen vorgeschrieben und in Normen gefasst. Die Messung dient der Beurteilung von Funktionsfähigkeit und Sicherheit und kann frühzeitig Mängel aufzeigen. Beispielsweise reagieren Schutzschalter erst bei unzweifelhafter Gefahr, wenn etwa an Fehlerstellen von Leitungen für Steckdosen mit Schutzkontakt thermische Leistungen ab rund 4000 Watt auftreten. Weiterhin dient die Isolationsmessung der systematischen Fehlersuche und ist eine Methode, Isolierstoffe und konstruktive Isolationslösungen zu beurteilen. (de)
  • An electrical isolation test is a Direct current (DC) or Alternating current (AC) resistance test that is performed between sub-circuit common and subsystem chassis to verify that a specified level of isolation resistance is met. Isolation testing may also be conducted between one or more electrical circuits of the same subsystem. The test often reveals problems that occurred during assembly, such as defective/wrong component, improper component placement/orientation and wire insulation or insulator defects that may cause inadvertent shorting or grounding to chassis, in turn, compromising electrical circuit quality and product safety. Isolation resistance measurements may be achieved using a high input impedance ohmmeter, digital multimeter (DMM) or current-limited Hipot test instrument. The selected equipment should not over stress sensitive electronic components comprising the subsystem. The test limits should also consider semiconductor components within the subsystem that may be activated by the potentials imposed by each type of test instrumentation. A minimum acceptable resistance value is usually specified (typically in the mega ohm (MΩ) range per circuit tested). Multiple circuits having a common return may be tested simultaneously, provided the minimum allowable resistance value is based on the number of circuits in parallel. Five basic isolation test configurations exist: 1. * Single Un-referenced End-Circuit – isolation between one input signal and circuit chassis/common ground. 2. * Multiple Un-referenced End-Circuits with a single return – isolation between several input signals and circuit chassis/common ground. 3. * Subsystem with Isolated Common – isolation between signal input and common ground. 4. * Common Chassis Ground – isolation between circuit common and chassis (chassis grounded). 5. * Isolated Circuit Common – isolation between circuit common and chassis (chassis floating). Isolation measurements are made with the assembly or subsystem unpowered and disconnected from any support equipment. (en)
dbo:wikiPageID
  • 36388598 (xsd:integer)
dbo:wikiPageLength
  • 2907 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 910791840 (xsd:integer)
dbo:wikiPageWikiLink
dbp:wikiPageUsesTemplate
dcterms:subject
gold:hypernym
rdf:type
rdfs:comment
  • اختبار العزل الكهربي هو اختبار مقاومة التيار المستمر (DC).ويهدف الاختبار إلى التحقق من: * وصول النظام إلى المستوي المطلوب من العزل. * اكتشاف المشاكل التي حدثت أثناء عملية التوصيل والتركيب. * اكتشاف عيوب العازل، التي تؤدي إلى تقليل المقاومة. * التأكد من جودة وكفاءة الدائرة الكهربية، وسلامة النظام. (ar)
  • Eine Isolationsmessung ist eine Messung des Isolationswiderstands und dient der Prüfung der Isolation, um deren Sicherheit oder Fehlerfreiheit zu erkennen. Der Nachweis des Isolationswiderstandes durch Messungen ist gesetzlich für elektrische Betriebsmittel in vielen Zusammenhängen vorgeschrieben und in Normen gefasst. Die Messung dient der Beurteilung von Funktionsfähigkeit und Sicherheit und kann frühzeitig Mängel aufzeigen. Beispielsweise reagieren Schutzschalter erst bei unzweifelhafter Gefahr, wenn etwa an Fehlerstellen von Leitungen für Steckdosen mit Schutzkontakt thermische Leistungen ab rund 4000 Watt auftreten. Weiterhin dient die Isolationsmessung der systematischen Fehlersuche und ist eine Methode, Isolierstoffe und konstruktive Isolationslösungen zu beurteilen. (de)
  • An electrical isolation test is a Direct current (DC) or Alternating current (AC) resistance test that is performed between sub-circuit common and subsystem chassis to verify that a specified level of isolation resistance is met. Isolation testing may also be conducted between one or more electrical circuits of the same subsystem. The test often reveals problems that occurred during assembly, such as defective/wrong component, improper component placement/orientation and wire insulation or insulator defects that may cause inadvertent shorting or grounding to chassis, in turn, compromising electrical circuit quality and product safety. (en)
rdfs:label
  • اختبار العزل الكهربي (ar)
  • Isolationsmessung (de)
  • Electrical isolation test (en)
owl:sameAs
prov:wasDerivedFrom
foaf:isPrimaryTopicOf
is dbo:wikiPageRedirects of
is dbo:wikiPageWikiLink of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License