Dielectric complex reluctance is a scalar measurement of a passive dielectric circuit (or element within that circuit) dependent on sinusoidal voltage and sinusoidal electric induction flux, and this is determined by deriving the ratio of their complex effective amplitudes. The units of dielectric complex reluctance are (inverse Farads - see Daraf) [Ref. 1-3]. As seen above, dielectric complex reluctance is a phasor represented as uppercase Z epsilon where: Where: * is the imaginary unit * is the phase of voltage * is the phase of electric induction flux * is the phase difference Where:

Property Value
dbo:abstract
  • Dielectric complex reluctance is a scalar measurement of a passive dielectric circuit (or element within that circuit) dependent on sinusoidal voltage and sinusoidal electric induction flux, and this is determined by deriving the ratio of their complex effective amplitudes. The units of dielectric complex reluctance are (inverse Farads - see Daraf) [Ref. 1-3]. As seen above, dielectric complex reluctance is a phasor represented as uppercase Z epsilon where: and represent the voltage (complex effective amplitude) and represent the electric induction flux (complex effective amplitude), lowercase z epsilon, is the real part of dielectric reluctance The "lossless" dielectric reluctance, lowercase z epsilon, is equal to the absolute value (modulus) of the dielectric complex reluctance. The argument distinguishing the "lossy" dielectric complex reluctance from the "lossless" dielectric reluctance is equal to the natural number raised to a power equal to: Where: * is the imaginary unit * is the phase of voltage * is the phase of electric induction flux * is the phase difference The "lossy" dielectric complex reluctance represents a dielectric circuit element's resistance to not only electric induction flux but also to changes in electric induction flux. When applied to harmonic regimes, this formality is similar to Ohm's Law in ideal AC circuits. In dielectric circuits, a dielectric material has a dielectric complex reluctance equal to: Where: * is the length of the circuit element * is the cross-section of the circuit element * is the complex dielectric permeability (en)
dbo:wikiPageID
  • 2751642 (xsd:integer)
dbo:wikiPageLength
  • 2692 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 868532058 (xsd:integer)
dbo:wikiPageWikiLink
dcterms:subject
rdfs:comment
  • Dielectric complex reluctance is a scalar measurement of a passive dielectric circuit (or element within that circuit) dependent on sinusoidal voltage and sinusoidal electric induction flux, and this is determined by deriving the ratio of their complex effective amplitudes. The units of dielectric complex reluctance are (inverse Farads - see Daraf) [Ref. 1-3]. As seen above, dielectric complex reluctance is a phasor represented as uppercase Z epsilon where: Where: * is the imaginary unit * is the phase of voltage * is the phase of electric induction flux * is the phase difference Where: (en)
rdfs:label
  • Dielectric complex reluctance (en)
owl:sameAs
prov:wasDerivedFrom
foaf:isPrimaryTopicOf
is dbo:wikiPageWikiLink of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License