An Entity of Type: Thing, from Named Graph: http://dbpedia.org, within Data Space: dbpedia.org

The Clarke Error Grid Analysis (EGA) was developed in 1987 to quantify clinical accuracy of patient estimates of their current blood glucose as compared to the blood glucose value obtained in their meter. It was then used to quantify the clinical accuracy of blood glucose estimates generated by meters as compared to a reference value. A description of the EGA appeared in Diabetes Care in 1987. Eventually, the EGA became accepted as one of the “gold standards” for determining the accuracy of blood glucose meters.

Property Value
dbo:abstract
  • Die Error-Grid-Analyse (kurz: EGA; auch Fehlerrasteranalyse) dient der Bewertung der klinischen Genauigkeit der Blutzuckermesswerte im Vergleich zu einem Referenzwert. Sie wurde u. a. von W. Clarke (Department of Pediatrics, University of Virginia Medical School, Charlottesville) in den 1970er Jahren entwickelt.Ursprünglich diente sie der Bestimmung der klinischen Genauigkeit der Patientenmeinung über den aktuellen Blutzuckerwert im Vergleich zu jenem Wert, den der Patient mit seinem Gerät zur Blutzuckerselbstkontrolle (Self Monitoring of Blood Glucose, SMBG) erhalten hatte.Später wurde diese Analyse verstärkt eingesetzt, um die klinische Genauigkeit der mit den Messgeräten zur Blutzuckerselbstkontrolle ermittelten Werte mit einem Referenzwert zu vergleichen. Eine Beschreibung der EGA erschien in der Fachzeitschrift „Diabetes Care“ im Jahr 1987.Schließlich wurde die Error Grid Analyse zu einem der „Gold-Standards“ zur Ermittlung der Genauigkeit von Blutzuckermessgeräten. Das Grid (Gitter, Raster) ordnet die ermittelten Blutzuckerwerte eines zu beurteilenden Messgerätes und des Referenzgerätes in fünf Regionen ein. * Region A beinhaltet alle Werte, die eine maximale Abweichung von 20 % vom Referenzwert aufweisen. * Region B hat alle Werte, die zwar mehr als 20 % vom Referenzwert abweichen, aber nicht zu einer Entscheidung führen, die eine fehlerhafte Auswirkung auf die Therapie des Patienten haben. * Region C, hier befinden sich jene Ergebnisse, die unnötige Entscheidungen zur Folge haben. * Region D zeigt alle Werte, die einen möglicherweise gefährlichen Fehler bei der Erkennung einer Hypo- oder Hyperglykämie anzeigen und in der * Region E sind alle Ergebnisse, die eine Verwechslung in der Behandlung einer Hypoglykämie oder Hyperglykämie nach sich ziehen würden und umgekehrt. (de)
  • The Clarke Error Grid Analysis (EGA) was developed in 1987 to quantify clinical accuracy of patient estimates of their current blood glucose as compared to the blood glucose value obtained in their meter. It was then used to quantify the clinical accuracy of blood glucose estimates generated by meters as compared to a reference value. A description of the EGA appeared in Diabetes Care in 1987. Eventually, the EGA became accepted as one of the “gold standards” for determining the accuracy of blood glucose meters. The grid breaks down a scatterplot of a reference glucose meter and an evaluated glucose meter into five regions: * Region A are those values within 20% of the reference sensor, * Region B contains points that are outside of 20% but would not lead to inappropriate treatment, * Region C are those points leading to unnecessary treatment, * Region D are those points indicating a potentially dangerous failure to detect hypoglycemia or hyperglycemia, and * Region E are those points that would confuse treatment of hypoglycemia for hyperglycemia and vice versa. (en)
dbo:thumbnail
dbo:wikiPageID
  • 12767023 (xsd:integer)
dbo:wikiPageLength
  • 1981 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1085380075 (xsd:integer)
dbo:wikiPageWikiLink
dbp:wikiPageUsesTemplate
dcterms:subject
rdfs:comment
  • Die Error-Grid-Analyse (kurz: EGA; auch Fehlerrasteranalyse) dient der Bewertung der klinischen Genauigkeit der Blutzuckermesswerte im Vergleich zu einem Referenzwert. Sie wurde u. a. von W. Clarke (Department of Pediatrics, University of Virginia Medical School, Charlottesville) in den 1970er Jahren entwickelt.Ursprünglich diente sie der Bestimmung der klinischen Genauigkeit der Patientenmeinung über den aktuellen Blutzuckerwert im Vergleich zu jenem Wert, den der Patient mit seinem Gerät zur Blutzuckerselbstkontrolle (Self Monitoring of Blood Glucose, SMBG) erhalten hatte.Später wurde diese Analyse verstärkt eingesetzt, um die klinische Genauigkeit der mit den Messgeräten zur Blutzuckerselbstkontrolle ermittelten Werte mit einem Referenzwert zu vergleichen. Eine Beschreibung der EGA ersc (de)
  • The Clarke Error Grid Analysis (EGA) was developed in 1987 to quantify clinical accuracy of patient estimates of their current blood glucose as compared to the blood glucose value obtained in their meter. It was then used to quantify the clinical accuracy of blood glucose estimates generated by meters as compared to a reference value. A description of the EGA appeared in Diabetes Care in 1987. Eventually, the EGA became accepted as one of the “gold standards” for determining the accuracy of blood glucose meters. (en)
rdfs:label
  • Error-Grid-Analyse (de)
  • Clarke Error Grid (en)
owl:sameAs
prov:wasDerivedFrom
foaf:depiction
foaf:isPrimaryTopicOf
is dbo:wikiPageRedirects of
is dbo:wikiPageWikiLink of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License