An auscultatory gap, also known as the silent gap, is a period of diminished or absent Korotkoff sounds during the manual measurement of blood pressure. It is associated with reduced peripheral blood flow caused by changes in the pulse wave. The improper interpretation of this gap may lead to blood pressure monitoring errors, such as an underestimation of systolic blood pressure and/or an overestimation of diastolic blood pressure. In order to correct for an auscultatory gap, the radial pulse should be monitored by palpation. It is therefore recommended to palpate and auscultate when manually recording a patient's blood pressure. Typically, the blood pressure obtained via palpation is around 10 mmHg lower than the pressure obtained via auscultation. In general, the examiner can avoid being

Property Value
dbo:abstract
  • An auscultatory gap, also known as the silent gap, is a period of diminished or absent Korotkoff sounds during the manual measurement of blood pressure. It is associated with reduced peripheral blood flow caused by changes in the pulse wave. The improper interpretation of this gap may lead to blood pressure monitoring errors, such as an underestimation of systolic blood pressure and/or an overestimation of diastolic blood pressure. In order to correct for an auscultatory gap, the radial pulse should be monitored by palpation. It is therefore recommended to palpate and auscultate when manually recording a patient's blood pressure. Typically, the blood pressure obtained via palpation is around 10 mmHg lower than the pressure obtained via auscultation. In general, the examiner can avoid being confused by an auscultatory gap by always inflating a blood pressure cuff to 20-40 mmHg higher than the pressure required to occlude the brachial pulse. (en)
dbo:wikiPageID
  • 7794672 (xsd:integer)
dbo:wikiPageLength
  • 3966 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1014700614 (xsd:integer)
dbo:wikiPageWikiLink
dbp:wikiPageUsesTemplate
dct:subject
gold:hypernym
rdf:type
rdfs:comment
  • An auscultatory gap, also known as the silent gap, is a period of diminished or absent Korotkoff sounds during the manual measurement of blood pressure. It is associated with reduced peripheral blood flow caused by changes in the pulse wave. The improper interpretation of this gap may lead to blood pressure monitoring errors, such as an underestimation of systolic blood pressure and/or an overestimation of diastolic blood pressure. In order to correct for an auscultatory gap, the radial pulse should be monitored by palpation. It is therefore recommended to palpate and auscultate when manually recording a patient's blood pressure. Typically, the blood pressure obtained via palpation is around 10 mmHg lower than the pressure obtained via auscultation. In general, the examiner can avoid being (en)
rdfs:label
  • Auscultatory gap (en)
owl:sameAs
prov:wasDerivedFrom
foaf:isPrimaryTopicOf
is dbo:wikiPageRedirects of
is dbo:wikiPageWikiLink of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License