dbo:abstract
|
- The terms "relative fluorescence units" (RFU) and "RFU peak" refer to measurements in electrophoresis methods, such as for DNA analysis. A "relative fluorescence unit" is a unit of measurement used in analysis which employs fluorescence detection. Fluorescence is detected using a charged coupled device (CCD) array, when the labeled fragments, which are separated within a capillary by using electrophoresis, are energized by laser light and travel across the detection window. A computer program measures the results, determining the quantity or size of the fragments, at each data point, from the level of fluorescence intensity. Samples which contain higher quantities of amplified DNA will have higher corresponding RFU values. An "RFU peak" is a relative maximum point along a graph of the analyzed data. The data can be normalized to DNA input or additional normalizing genes. The RFU heights can range from 0 to several thousands. (en)
- Относительная единица флуоресценции (ОЕФ) — внесистемная единица интенсивности флуоресценции по квазиабсолютной шкале, нормированной на максимум излучения опорного раствора флуоресцеина. За опорную (1 ОЕФ) принимают флуоресцирующую способность водного (pH=5,5) раствора натриевой соли флуоресцеина «Уранин А» концентрацией 1 мг/л на длине волны 514 нм при длине волны возбуждении 405 нм. Численно значение в ОЕФ равно отношению регистрируемой прибором интенсивности эмиссионного излучения характеризуемого вещества или материала к опорной интенсивности эмиссионного излучения, измеренной при аналогичных условиях. Значение в ОЕФ характеризует аналитическую способность (чувствительность) прибора или флуоресцентную, поглощающую и рассеивающую способности вещества или материала. Единицы ОЕФ допущены к применению в Российской Федерации и позволяют обеспечить единство измерений в области люминесценции и проводить поверку спектрофлуориметров, ПЦР-анализаторов и других средств измерения на основе флуоресценции. (ru)
|
dbo:wikiPageID
| |
dbo:wikiPageLength
|
- 5369 (xsd:nonNegativeInteger)
|
dbo:wikiPageRevisionID
| |
dbo:wikiPageWikiLink
| |
dbp:wikiPageUsesTemplate
| |
dcterms:subject
| |
rdf:type
| |
rdfs:comment
|
- The terms "relative fluorescence units" (RFU) and "RFU peak" refer to measurements in electrophoresis methods, such as for DNA analysis. A "relative fluorescence unit" is a unit of measurement used in analysis which employs fluorescence detection. Fluorescence is detected using a charged coupled device (CCD) array, when the labeled fragments, which are separated within a capillary by using electrophoresis, are energized by laser light and travel across the detection window. A computer program measures the results, determining the quantity or size of the fragments, at each data point, from the level of fluorescence intensity. Samples which contain higher quantities of amplified DNA will have higher corresponding RFU values. (en)
- Относительная единица флуоресценции (ОЕФ) — внесистемная единица интенсивности флуоресценции по квазиабсолютной шкале, нормированной на максимум излучения опорного раствора флуоресцеина. За опорную (1 ОЕФ) принимают флуоресцирующую способность водного (pH=5,5) раствора натриевой соли флуоресцеина «Уранин А» концентрацией 1 мг/л на длине волны 514 нм при длине волны возбуждении 405 нм. Численно значение в ОЕФ равно отношению регистрируемой прибором интенсивности эмиссионного излучения характеризуемого вещества или материала к опорной интенсивности эмиссионного излучения, измеренной при аналогичных условиях. Значение в ОЕФ характеризует аналитическую способность (чувствительность) прибора или флуоресцентную, поглощающую и рассеивающую способности вещества или материала. (ru)
|
rdfs:label
|
- Relative fluorescence units (en)
- Относительная единица флуоресценции (ru)
|
owl:sameAs
| |
prov:wasDerivedFrom
| |
foaf:isPrimaryTopicOf
| |
is dbo:wikiPageDisambiguates
of | |
is dbo:wikiPageRedirects
of | |
is dbo:wikiPageWikiLink
of | |
is foaf:primaryTopic
of | |