Short-circuit inductance of a real linear two-winding transformer is inductance measured across the primary or secondary winding when the other winding is short-circuited. The method of measuring the short circuit inductance is described in industrial standard. The industrial standard also stipulates a method for obtaining the coupling factor by combining it with the open circuit inductance value. Where * k is coupling coefficient * L1 is primary self-inductance * L2 is secondary self-inductance where

AttributesValues
rdfs:label
  • Kurzschlussinduktivität (de)
  • 短絡インダクタンス (ja)
  • Short-circuit inductance (en)
  • Індуктивність короткого замикання (uk)
  • 短路電感 (zh)
rdfs:comment
  • Die Kurzschlussinduktivität ist in der Elektrotechnik die Induktivität eines Transformators, wie sie von einer Seite aus, der Primärseite oder der Sekundärseite des Transformators, gemessen wird, wobei die andere Seite kurzgeschlossen ist. Dieser Wert wird oft mit der Streuinduktivität des Transformators verwechselt. (de)
  • 短絡インダクタンス(たんらくいんだくたんす)、(英: Short-circuit inductance)は、変圧器(トランス)の一次巻線あるいは二次巻線の一方を短絡して他方から測った場合のインダクタンスである。一般に変圧器の漏れインダクタンスと呼ばれることが多い。しかし、漏れインダクタンスという用語は電気学会および書籍関係においては、一次巻線あるいは二次巻線の一方の巻線とし、他方の巻線と鎖交しない磁束(漏れ磁束)によって生じるインダクタンスであるとされており、短絡インダクタンスを慣用的に漏れインダクタンスと呼ぶことで混乱を生じている。 (ja)
  • 短路電感,(英文:Short-circuit inductance)是,變壓器的初級線圈或次級線圈的其中一方使其短路,從另一方測得的電感。一般多稱為漏電感(或漏感)。但漏電感的用語在電機電子工程師學會及相關書籍中,指的是初級線圈或次級線圈的一方互為(magnetic flux linkage),另一方的線圈未交鏈的磁通(或)所產生的電感,短路電感成為慣用的漏電感的說法,故導致混亂。 (zh)
  • Short-circuit inductance of a real linear two-winding transformer is inductance measured across the primary or secondary winding when the other winding is short-circuited. The method of measuring the short circuit inductance is described in industrial standard. The industrial standard also stipulates a method for obtaining the coupling factor by combining it with the open circuit inductance value. Where * k is coupling coefficient * L1 is primary self-inductance * L2 is secondary self-inductance where (en)
  • Індуктивність короткого замикання справжнього лінійного трансформатора з двома обмотками - це індуктивність, виміряна через первинну або вторинну обмотку, коли інша обмотка має коротке замикання. Вимірювання індуктивності короткого замикання є альтернативою або доповненням вимірювань індуктивності відкритого ланцюга і дає різні приближення для коефіцієнта зв'язку та інших похідних величин. Яка методологія вимірювання є найбільш актуальною, залежить від застосування. Де * k - коефіцієнт зв'язку * L 1 - первинна самоіндуктивність * L 2 - вторинна самоіндуктивність де (uk)
foaf:depiction
  • http://commons.wikimedia.org/wiki/Special:FilePath/Leakage_mesure.gif
  • http://commons.wikimedia.org/wiki/Special:FilePath/Transformer_eq2.gif
dct:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
sameAs
dbp:wikiPageUsesTemplate
thumbnail
has abstract
  • Die Kurzschlussinduktivität ist in der Elektrotechnik die Induktivität eines Transformators, wie sie von einer Seite aus, der Primärseite oder der Sekundärseite des Transformators, gemessen wird, wobei die andere Seite kurzgeschlossen ist. Dieser Wert wird oft mit der Streuinduktivität des Transformators verwechselt. (de)
  • Short-circuit inductance of a real linear two-winding transformer is inductance measured across the primary or secondary winding when the other winding is short-circuited. The method of measuring the short circuit inductance is described in industrial standard. The industrial standard also stipulates a method for obtaining the coupling factor by combining it with the open circuit inductance value. Measured primary and secondary short-circuit inductances may be considered as constituent parts of primary and secondary self-inductances. They are derived by using Ho-Thevenin's theorem from the equivalent inductance of the three-terminal equivalent circuit as follows. Then they are related according to the coupling factor as, Where * k is coupling coefficient * L1 is primary self-inductance * L2 is secondary self-inductance Short-circuit inductance measurement is used in conjunction with open-circuit inductance measurements to obtain various derived quantities like , the inductive coupling factor and , the inductive leakage factor. is derived according to: where * is the short-circuit measurement of primary or secondary inductance * is the corresponding open-circuit measurement of primary or secondary inductance Other transformer parameters like leakage inductance and mutual inductance which cannot be directly measured may be defined in terms of k. Short-circuit inductance is one of the parameters that determines the resonance frequency of the magnetic phase synchronous coupling in a resonant transformer and wireless power transfer. Short-circuit inductance is the main component of the current-limiting parameter in leakage transformer applications. (en)
  • 短絡インダクタンス(たんらくいんだくたんす)、(英: Short-circuit inductance)は、変圧器(トランス)の一次巻線あるいは二次巻線の一方を短絡して他方から測った場合のインダクタンスである。一般に変圧器の漏れインダクタンスと呼ばれることが多い。しかし、漏れインダクタンスという用語は電気学会および書籍関係においては、一次巻線あるいは二次巻線の一方の巻線とし、他方の巻線と鎖交しない磁束(漏れ磁束)によって生じるインダクタンスであるとされており、短絡インダクタンスを慣用的に漏れインダクタンスと呼ぶことで混乱を生じている。 (ja)
  • Індуктивність короткого замикання справжнього лінійного трансформатора з двома обмотками - це індуктивність, виміряна через первинну або вторинну обмотку, коли інша обмотка має коротке замикання. Вимірювання індуктивності короткого замикання є альтернативою або доповненням вимірювань індуктивності відкритого ланцюга і дає різні приближення для коефіцієнта зв'язку та інших похідних величин. Яка методологія вимірювання є найбільш актуальною, залежить від застосування. Вимірювані первинні та вторинні індуктивність короткого замикання можуть розглядатися як складові частини первинної та вторинної самоіндуктивності; вони пов'язані відповідно до коефіцієнта зв'язку як, Де * k - коефіцієнт зв'язку * L 1 - первинна самоіндуктивність * L 2 - вторинна самоіндуктивність Вимірювання індуктивності короткого замикання використовується спільно з вимірюваннями індуктивності відкритого контуру для отримання різних похідних величин, таких як , коефіцієнт індуктивної зв'язку і , індуктивний коефіцієнт витоку. виводиться відповідно до: де * - вимірювання короткого замикання первинної або вторинної індуктивності * - відповідне вимірювання відкритого контуру первинної або вторинної індуктивності Інші параметри трансформатора, такі як індуктивність витоку та взаємна індуктивність, які неможливо безпосередньо виміряти, можуть бути визначені через k. Індуктивність короткого замикання - один з параметрів, що визначає резонансну частоту синхронної зв'язку магнітної фази в резонансному трансформаторі та бездротовій передачі електроенергії . Індуктивність короткого замикання є основною складовою параметра обмеження струму в програмах трансформаторів витоку . (uk)
  • 短路電感,(英文:Short-circuit inductance)是,變壓器的初級線圈或次級線圈的其中一方使其短路,從另一方測得的電感。一般多稱為漏電感(或漏感)。但漏電感的用語在電機電子工程師學會及相關書籍中,指的是初級線圈或次級線圈的一方互為(magnetic flux linkage),另一方的線圈未交鏈的磁通(或)所產生的電感,短路電感成為慣用的漏電感的說法,故導致混亂。 (zh)
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git147 as of Sep 06 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3331 as of Sep 2 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 65 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software