About: Guard tone     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : yago:Whole100003553, within Data Space : dbpedia.org associated with source document(s)
QRcode icon
http://dbpedia.org/describe/?url=http%3A%2F%2Fdbpedia.org%2Fresource%2FGuard_tone

Guard tone is a feature of wireline modems. The guard tone is sent by the answering modem after it has sent the answer tone. It is a single continuous tone with a frequency of either 1800 Hz or 550 Hz, sent at a level of -6dB or -3dB, respectively, below the level of the transmitted data signal power. It is used with V.22 and V.22bis modulation modes to prevent the high-band data signal from interfering with the operation of billing apparatus in certain countries where in-band signalling was commonplace in the 20th century.

AttributesValues
rdf:type
rdfs:label
  • Guard tone (en)
rdfs:comment
  • Guard tone is a feature of wireline modems. The guard tone is sent by the answering modem after it has sent the answer tone. It is a single continuous tone with a frequency of either 1800 Hz or 550 Hz, sent at a level of -6dB or -3dB, respectively, below the level of the transmitted data signal power. It is used with V.22 and V.22bis modulation modes to prevent the high-band data signal from interfering with the operation of billing apparatus in certain countries where in-band signalling was commonplace in the 20th century. (en)
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
Link from a Wikipage to an external page
sameAs
dbp:wikiPageUsesTemplate
has abstract
  • Guard tone is a feature of wireline modems. The guard tone is sent by the answering modem after it has sent the answer tone. It is a single continuous tone with a frequency of either 1800 Hz or 550 Hz, sent at a level of -6dB or -3dB, respectively, below the level of the transmitted data signal power. It is used with V.22 and V.22bis modulation modes to prevent the high-band data signal from interfering with the operation of billing apparatus in certain countries where in-band signalling was commonplace in the 20th century. 1800 Hz is used in the UK and some Commonwealth countries, while 550 Hz is used in some Scandinavian countries. Guard tones are not used in North America. The guard tone is controlled by the &G AT command of the Hayes command set. North American Bell 103-style modems (300 bit/s) were incompatible with UK in-band signalling (the modem tones would disconnect the call) unless a guard tone is provided. Most of these (now-obsolete) modems did not support any command set and were unusable for international calls. (en)
gold:hypernym
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (61 GB total memory, 49 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software