Asymmetrical flow field-flow fractionation (AF4) is most versatile and most widely used sub-technique within the family of field flow fractionation (FFF) methods. AF4 can be used in aqueous and organic solvents and is able to characterize nanoparticles, polymers and proteins. The theory for AF4 was conceived in 1986 and was established in 1987 and first published by Wahlund and Giddings. AF4 is distinct from symmetrical Flow FFF because it contains only one permeable wall so the cross-flow is caused only by the carrier liquid. The cross-flow is induced by the carrier liquid constantly exiting by way of the semi-permeable wall on the bottom of the channel.
Attributes | Values |
---|
rdf:type
| |
rdfs:label
| - Asymmetrischer-Fluss-Feldflussfraktionierung (de)
- Asymmetric flow field flow fractionation (en)
|
rdfs:comment
| - Asymmetrical flow field-flow fractionation (AF4) is most versatile and most widely used sub-technique within the family of field flow fractionation (FFF) methods. AF4 can be used in aqueous and organic solvents and is able to characterize nanoparticles, polymers and proteins. The theory for AF4 was conceived in 1986 and was established in 1987 and first published by Wahlund and Giddings. AF4 is distinct from symmetrical Flow FFF because it contains only one permeable wall so the cross-flow is caused only by the carrier liquid. The cross-flow is induced by the carrier liquid constantly exiting by way of the semi-permeable wall on the bottom of the channel. (en)
- Die Asymmetrischer-Fluss-Feld-Fluss-Fraktionierung (AF4/aFFFF, engl. asymmetric flow field-flow fractionation), oft auch als „asymmetrische “ bezeichnet, ist eine junge Trennmethode für die Fraktionierung und Analyse von Stoffen. Es handelt sich um eine Variante der Feld-Fluss-Fraktionierung (FFF). Die Detektion der eluierten Analyten erfolgt mit Hilfe von , Brechungsindexdetektoren und Lichtstreudetektoren. Die Kopplung der AF4 mit multiangle laser light scattering erlaubt die Analyse von Partikelgrößen ohne Verwendung von Größenstandards. (de)
|
foaf:depiction
| |
dct:subject
| |
Wikipage page ID
| |
Wikipage revision ID
| |
Link from a Wikipage to another Wikipage
| |
Link from a Wikipage to an external page
| |
sameAs
| |
dbp:wikiPageUsesTemplate
| |
thumbnail
| |
has abstract
| - Asymmetrical flow field-flow fractionation (AF4) is most versatile and most widely used sub-technique within the family of field flow fractionation (FFF) methods. AF4 can be used in aqueous and organic solvents and is able to characterize nanoparticles, polymers and proteins. The theory for AF4 was conceived in 1986 and was established in 1987 and first published by Wahlund and Giddings. AF4 is distinct from symmetrical Flow FFF because it contains only one permeable wall so the cross-flow is caused only by the carrier liquid. The cross-flow is induced by the carrier liquid constantly exiting by way of the semi-permeable wall on the bottom of the channel. (en)
- Die Asymmetrischer-Fluss-Feld-Fluss-Fraktionierung (AF4/aFFFF, engl. asymmetric flow field-flow fractionation), oft auch als „asymmetrische “ bezeichnet, ist eine junge Trennmethode für die Fraktionierung und Analyse von Stoffen. Es handelt sich um eine Variante der Feld-Fluss-Fraktionierung (FFF). Die AF4 ist in gewissen Molmassenbereichen (ca. 1 kDa–10 MDa) komplementär mit der Größenausschlusschromatographie (GPC/SEC). Während bei der SEC die Trennung aufgrund der molekülgrößenabhängigen Wechselwirkungen mit einer porösen stationären Phase erfolgt, wird bei der FFF ein senkrecht zur Flussrichtung angelegtes Feld verwendet. Mit der FFF ist es möglich, neben geladenen und ungeladenen Polymeren, Aggregaten und Proteinen selbst Viren zu analysieren. Trennungen erfolgen in einem Bereich von etwa 1 nm bis 100 µm. Die Detektion der eluierten Analyten erfolgt mit Hilfe von , Brechungsindexdetektoren und Lichtstreudetektoren. Die Kopplung der AF4 mit multiangle laser light scattering erlaubt die Analyse von Partikelgrößen ohne Verwendung von Größenstandards. Der Vorteil der FFF gegenüber der SEC besteht in ihrer Geschwindigkeit, dem Fehlen von Scherkräften und Wechselwirkungen zur stationären Phase und dem dynamischen Separationsbereich. Die Trennung ist schonend und hochauflösend. Analyten können gelöst oder dispergiert vorliegen. (de)
|
gold:hypernym
| |
prov:wasDerivedFrom
| |
page length (characters) of wiki page
| |
foaf:isPrimaryTopicOf
| |
is Link from a Wikipage to another Wikipage
of | |
is Wikipage redirect
of | |
is foaf:primaryTopic
of | |