About: Analytical ultracentrifugation     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : owl:Thing, within Data Space : dbpedia.org associated with source document(s)
QRcode icon
http://dbpedia.org/describe/?url=http%3A%2F%2Fdbpedia.org%2Fresource%2FAnalytical_ultracentrifugation

Analytical ultracentrifugation is an analytical technique which combines an ultracentrifuge with optical monitoring systems. In an analytical ultracentrifuge (commonly abbreviated as AUC), a sample’s sedimentation profile is monitored in real time by an optical detection system. The sample is detected via ultraviolet light absorption and/or interference optical refractive index sensitive system, monitored by light-sensitive diode array or by film in the older machines. The operator can thus observe the change of sample concentration versus the axis of the rotation profile with time as a result of the applied centrifugal field. With modern instrumentation, these observations are electronically digitized and stored for further mathematical analysis.

AttributesValues
rdfs:label
  • Analytische Ultrazentrifugation (de)
  • Analytical ultracentrifugation (en)
rdfs:comment
  • Die Analytische Ultrazentrifugation (AUZ) ist ein Analyse-Verfahren, welches die Bewegung und Position suspendierter Partikel in einem Zentrifugalfeld mittels optischer Messverfahren erfasst. Am häufigsten werden dabei Sedimentations- und Diffusionskoeffizienten bestimmt, wodurch Rückschlüsse auf Form, Größe, Dichte oder Masse der untersuchten Partikel oder Biomoleküle gezogen werden können. Maßgeblich wurde die Technik von The Svedberg entwickelt. (de)
  • Analytical ultracentrifugation is an analytical technique which combines an ultracentrifuge with optical monitoring systems. In an analytical ultracentrifuge (commonly abbreviated as AUC), a sample’s sedimentation profile is monitored in real time by an optical detection system. The sample is detected via ultraviolet light absorption and/or interference optical refractive index sensitive system, monitored by light-sensitive diode array or by film in the older machines. The operator can thus observe the change of sample concentration versus the axis of the rotation profile with time as a result of the applied centrifugal field. With modern instrumentation, these observations are electronically digitized and stored for further mathematical analysis. (en)
foaf:depiction
  • http://commons.wikimedia.org/wiki/Special:FilePath/HD.6D.647_(13472499543).jpg
  • http://commons.wikimedia.org/wiki/Special:FilePath/Rotors_for_Analytical_Ultracentrifuge,_Jan_2020.jpg
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
Link from a Wikipage to an external page
sameAs
dbp:wikiPageUsesTemplate
thumbnail
has abstract
  • Die Analytische Ultrazentrifugation (AUZ) ist ein Analyse-Verfahren, welches die Bewegung und Position suspendierter Partikel in einem Zentrifugalfeld mittels optischer Messverfahren erfasst. Am häufigsten werden dabei Sedimentations- und Diffusionskoeffizienten bestimmt, wodurch Rückschlüsse auf Form, Größe, Dichte oder Masse der untersuchten Partikel oder Biomoleküle gezogen werden können. Maßgeblich wurde die Technik von The Svedberg entwickelt. (de)
  • Analytical ultracentrifugation is an analytical technique which combines an ultracentrifuge with optical monitoring systems. In an analytical ultracentrifuge (commonly abbreviated as AUC), a sample’s sedimentation profile is monitored in real time by an optical detection system. The sample is detected via ultraviolet light absorption and/or interference optical refractive index sensitive system, monitored by light-sensitive diode array or by film in the older machines. The operator can thus observe the change of sample concentration versus the axis of the rotation profile with time as a result of the applied centrifugal field. With modern instrumentation, these observations are electronically digitized and stored for further mathematical analysis. The information that can be obtained from an analytical ultracentrifuge includes the gross shape of macromolecules, conformational changes in macromolecules, and size distributions of macromolecules. With AUC it is possible to gain information on the number and subunit stoichiometry of non-covalent complexes and equilibrium constants of macromolecules such as proteins, DNA, nanoparticles or other assemblies from different molecule classes. The simplest measurement to be obtained is the sedimentation coefficient, which depends upon the size of the molecules being sedimented. This is the ratio of a particle's sedimentation velocity to the applied acceleration causing the sedimentation. Analytical ultracentrifugation has recently seen a rise in use because of increased ease of analysis with modern computers and the development of software, including a National Institutes of Health supported software package, SedFit. (en)
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (61 GB total memory, 46 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software