A physical configuration audit (PCA) is the formal examination of the "as-built" configuration of aconfiguration item against its technical documentation to establish or verify the configuration item's product baseline.The PCA is used to examine the actual configuration of the configuration item (CI) that is representative of the product configuration in order to verify that the related design documentation matches the design of the deliverable CI. It is also used to validate many of the supporting processes that the contractor uses in the production of the CI. This is also used to verify that any elements of the CI that were redesigned after the completion of the also meet the requirements of the CI's performance specification. Additional PCAs may be accomplished later during CI producti

AttributesValues
rdf:type
rdfs:label
  • Physical configuration audit (en)
  • 實體配置審核 (zh)
rdfs:comment
  • 實體配置審核(physical configuration audit)簡稱PCA,是在配置管理中,對於形態項目是否符合其技術文件的正式檢驗,目的是建立或驗證配置項目的基準。 實體配置審核是檢驗配置項目(代表產品的配置)的實際配置,目的是為了確認相關的設計文件符合要交付配置項目的設計。實體配置審核也用來驗證承包商用來產生配置項目的相關支持過程。機能配置審核(functional configuration audit)完成後,也會用實體配置審核來確認配置項目是否有重新設計,以符合配置項目性能規格的需求。若是出現以下的情形,也可能在配置項目完成後再進行額外的實體配置審核: * 原先的產線已經「停線」幾年,之後要重新生產。 * 原來產生配置項目的方式太過複雜,或是不易生產,因此希望找新的供應商或承包商。 在上述情形下,不論承包商或是管理者是否有控管細節的產品設計,都建議重新進行審核 (zh)
  • A physical configuration audit (PCA) is the formal examination of the "as-built" configuration of aconfiguration item against its technical documentation to establish or verify the configuration item's product baseline.The PCA is used to examine the actual configuration of the configuration item (CI) that is representative of the product configuration in order to verify that the related design documentation matches the design of the deliverable CI. It is also used to validate many of the supporting processes that the contractor uses in the production of the CI. This is also used to verify that any elements of the CI that were redesigned after the completion of the also meet the requirements of the CI's performance specification. Additional PCAs may be accomplished later during CI producti (en)
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
Link from a Wikipage to an external page
sameAs
dbp:wikiPageUsesTemplate
has abstract
  • A physical configuration audit (PCA) is the formal examination of the "as-built" configuration of aconfiguration item against its technical documentation to establish or verify the configuration item's product baseline.The PCA is used to examine the actual configuration of the configuration item (CI) that is representative of the product configuration in order to verify that the related design documentation matches the design of the deliverable CI. It is also used to validate many of the supporting processes that the contractor uses in the production of the CI. This is also used to verify that any elements of the CI that were redesigned after the completion of the also meet the requirements of the CI's performance specification. Additional PCAs may be accomplished later during CI production if circumstances such as the following apply: * The original production line is "shut down" for several years and then production is restarted. * The production contract for manufacture of a CI with a fairly complex, or difficult-to-manufacture, design is awarded to a new contractor or vendor. This re-auditing in these circumstances is advisable regardless of whether the contractor or the government controls the detail production design. (en)
  • 實體配置審核(physical configuration audit)簡稱PCA,是在配置管理中,對於形態項目是否符合其技術文件的正式檢驗,目的是建立或驗證配置項目的基準。 實體配置審核是檢驗配置項目(代表產品的配置)的實際配置,目的是為了確認相關的設計文件符合要交付配置項目的設計。實體配置審核也用來驗證承包商用來產生配置項目的相關支持過程。機能配置審核(functional configuration audit)完成後,也會用實體配置審核來確認配置項目是否有重新設計,以符合配置項目性能規格的需求。若是出現以下的情形,也可能在配置項目完成後再進行額外的實體配置審核: * 原先的產線已經「停線」幾年,之後要重新生產。 * 原來產生配置項目的方式太過複雜,或是不易生產,因此希望找新的供應商或承包商。 在上述情形下,不論承包商或是管理者是否有控管細節的產品設計,都建議重新進行審核 (zh)
gold:hypernym
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is Wikipage redirect of
is Wikipage disambiguates of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software