About: Phoswich detector     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : yago:Whole100003553, within Data Space : dbpedia.org associated with source document(s)
QRcode icon
http://dbpedia.org/describe/?url=http%3A%2F%2Fdbpedia.org%2Fresource%2FPhoswich_detector&graph=http%3A%2F%2Fdbpedia.org&graph=http%3A%2F%2Fdbpedia.org

Phoswich detectors were developed to detect low-intensity, low-energy gamma rays, X-rays, as well as alpha and beta particles efficiently in a higher-energy ambient background. Some detector designs can measure and separately identify all energies simultaneously. A phoswich ("phosphor sandwich") is a combination of scintillators with dissimilar pulse shape characteristics optically coupled to each other and to a common PMT (or PMTs). Pulse shape analysis distinguishes the signals from the two scintillators, identifying in which scintillator the event occurred.

AttributesValues
rdf:type
rdfs:label
  • Détecteur phoswich (fr)
  • Phoswich detector (en)
rdfs:comment
  • Un détecteur phoswich (mot composé formé à partir de PHOSphore et sandWICH) est un détecteur de particules formé de deux scintillateurs utilisant des matériaux différents caractérisés par des signaux de réponse différents lorsqu'ils sont traversés par une particule énergétique. Dans ce montage les deux scintillateurs sont fixés l'un sur l'autre et sont traversés par la particule incidente. La forme du signal mesurée par un tube photomultiplicateur ou une photodiode située à l'arrière de ce dispositif présente une courbe qui permet de rejeter les détections dues au bruit de fond. Ces détecteurs sont utilisés pour mesurer l'énergie des rayons X et gamma mous dans des applications de médecine nucléaire et d'astronomie gamma et X. (fr)
  • Phoswich detectors were developed to detect low-intensity, low-energy gamma rays, X-rays, as well as alpha and beta particles efficiently in a higher-energy ambient background. Some detector designs can measure and separately identify all energies simultaneously. A phoswich ("phosphor sandwich") is a combination of scintillators with dissimilar pulse shape characteristics optically coupled to each other and to a common PMT (or PMTs). Pulse shape analysis distinguishes the signals from the two scintillators, identifying in which scintillator the event occurred. (en)
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
Link from a Wikipage to an external page
sameAs
dbp:wikiPageUsesTemplate
has abstract
  • Phoswich detectors were developed to detect low-intensity, low-energy gamma rays, X-rays, as well as alpha and beta particles efficiently in a higher-energy ambient background. Some detector designs can measure and separately identify all energies simultaneously. A phoswich ("phosphor sandwich") is a combination of scintillators with dissimilar pulse shape characteristics optically coupled to each other and to a common PMT (or PMTs). Pulse shape analysis distinguishes the signals from the two scintillators, identifying in which scintillator the event occurred. In 2010 development of a monolithic phoswich sensor technology was announced, departing from the discrete designs. This novel development, termed the continuous phoswich scintillator and detector, provides a number of bits of depth-of-interaction (DOI) information, a significant improvement over the 1 to 2 bits available previously with discrete phoswich scintillators. Phoswich applications are frequently seen in sensitive and low-background radiation sensors used in space research. (en)
  • Un détecteur phoswich (mot composé formé à partir de PHOSphore et sandWICH) est un détecteur de particules formé de deux scintillateurs utilisant des matériaux différents caractérisés par des signaux de réponse différents lorsqu'ils sont traversés par une particule énergétique. Dans ce montage les deux scintillateurs sont fixés l'un sur l'autre et sont traversés par la particule incidente. La forme du signal mesurée par un tube photomultiplicateur ou une photodiode située à l'arrière de ce dispositif présente une courbe qui permet de rejeter les détections dues au bruit de fond. Ces détecteurs sont utilisés pour mesurer l'énergie des rayons X et gamma mous dans des applications de médecine nucléaire et d'astronomie gamma et X. (fr)
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is Wikipage redirect of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software