About: Condensation particle counter     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : yago:WikicatDetectors, within Data Space : dbpedia.org associated with source document(s)
QRcode icon
http://dbpedia.org/describe/?url=http%3A%2F%2Fdbpedia.org%2Fresource%2FCondensation_particle_counter&graph=http%3A%2F%2Fdbpedia.org&graph=http%3A%2F%2Fdbpedia.org

A condensation particle counter or CPC is a particle counter that detects and counts aerosol particles by first enlarging them by using the particles as nucleation centers to create droplets in a supersaturated gas. Three techniques have been used to produce nucleation: * Adiabatic expansion using an expansion chamber. This was the original technique used by John Aitken in 1888. * Thermal diffusion. * Mixing of hot and cold gases.

AttributesValues
rdf:type
rdfs:label
  • Kondensationspartikelzähler (de)
  • Condensation particle counter (en)
rdfs:comment
  • Ein Kondensationspartikelzähler oder Kondensationskernzähler (englisch Condensation Particle Counter, kurz CPC, oder englisch Condensation Nucleus Counter, kurz CNC) ist ein optisches Messgerät, mit dem kleine Partikel in der Atmosphäre (Aerosole), mit Größen von wenigen Nanometern bis Mikrometern, erfasst werden können. Die physikalischen Prinzipien, die dem Messverfahren zugrunde liegen, sind die Streulichtmessung und der Umstand, dass in einer Atmosphäre mit übersättigtem Dampf Partikel als Kondensationskerne wirken können. Um eine Kondensation zu ermöglichen, werden die für die optische Erfassung zu kleinen Partikel durch heterogene Kondensation, von beispielsweise n-Butanol oder Wasser an ihre Oberfläche, vergrößert. Im Gegensatz zu fraktionierenden Verfahren zählt die Partikelmessung (de)
  • A condensation particle counter or CPC is a particle counter that detects and counts aerosol particles by first enlarging them by using the particles as nucleation centers to create droplets in a supersaturated gas. Three techniques have been used to produce nucleation: * Adiabatic expansion using an expansion chamber. This was the original technique used by John Aitken in 1888. * Thermal diffusion. * Mixing of hot and cold gases. (en)
foaf:depiction
  • http://commons.wikimedia.org/wiki/Special:FilePath/Cpc-my.svg
  • http://commons.wikimedia.org/wiki/Special:FilePath/Airborne_nanomaterials_detection_equipment.png
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
Link from a Wikipage to an external page
sameAs
dbp:wikiPageUsesTemplate
thumbnail
has abstract
  • Ein Kondensationspartikelzähler oder Kondensationskernzähler (englisch Condensation Particle Counter, kurz CPC, oder englisch Condensation Nucleus Counter, kurz CNC) ist ein optisches Messgerät, mit dem kleine Partikel in der Atmosphäre (Aerosole), mit Größen von wenigen Nanometern bis Mikrometern, erfasst werden können. Die physikalischen Prinzipien, die dem Messverfahren zugrunde liegen, sind die Streulichtmessung und der Umstand, dass in einer Atmosphäre mit übersättigtem Dampf Partikel als Kondensationskerne wirken können. Um eine Kondensation zu ermöglichen, werden die für die optische Erfassung zu kleinen Partikel durch heterogene Kondensation, von beispielsweise n-Butanol oder Wasser an ihre Oberfläche, vergrößert. Im Gegensatz zu fraktionierenden Verfahren zählt die Partikelmessung mit dem Kondensationspartikelzähler zu den integrierenden Verfahren. (de)
  • A condensation particle counter or CPC is a particle counter that detects and counts aerosol particles by first enlarging them by using the particles as nucleation centers to create droplets in a supersaturated gas. Three techniques have been used to produce nucleation: * Adiabatic expansion using an expansion chamber. This was the original technique used by John Aitken in 1888. * Thermal diffusion. * Mixing of hot and cold gases. The most usually used (also the most efficient) method is cooling by thermal diffusion. Most abundantly used working fluid is n-butanol; during last years water is also encountered in this use. Condensation particle counters are able to detect particles with dimensions from 2 nm and larger. This is of special importance because particles sized down from 50 nm are generally undetectable with conventional optical techniques. Usually the supersaturation is ca. 100…200 % in condensation chamber, despite the fact that heterogeneous nucleation (droplet growth on surface of a suspended solid particle) can occur at supersaturation as small as 1 %. The greater vapour content is needed because, according to surface science laws, the vapour pressure over a convex surface is less than over a plane, thus greater content of vapor in air is required to meet actual supersaturation criteria. This amount grows (vapor pressure decreases) along with decrease in particle size, the critical diameter for which condensation can occur at the present saturation level is called Kelvin diameter. The supersaturation level must, however, be small enough to prevent homogeneous nucleation (when liquid molecules collide so often that they form clusters – stable enough to ensure further growth is possible), which will produce false counts. This usually starts at ca. 300 % supersaturation. Operation of a diffusional thermal cooling CPC is depicted on the right. Air passes through a hollow block of porous material in contact with the working liquid, the block being heated to ensure high vapour content. Then the humified air enters the cooler where nucleation occur. Temperature difference between the heater and the cooler determines the supersaturation, which in its turn determines the minimal size of particles that will be detected (the greater the difference, the smaller particles get counted). As proper nucleation conditions occur in the center of the flow, sometimes incoming flow is divided: most of it undergoes filtering and forms the sheath flow, which the rest of flow, still containing particles, is inserted into via a capillary. The more uniform is obtained supersaturation, the sharper is particle minimal size cutoff. During the heterogeneous nucleation process in the nucleation chamber, particles grow up to 10…12 μm large and so are conveniently detected by usual techniques, such as laser nefelometry (measurement of light pulses scattered by the grown-up particles). (en)
gold:hypernym
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is Wikipage redirect of
is Wikipage disambiguates of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (61 GB total memory, 51 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software