An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a transducer (or sensor) that converts the activity of a specific ion dissolved in a solution into an electrical potential. The voltage is theoretically dependent on the logarithm of the ionic activity, according to the Nernst equation. Ion-selective electrodes are used in analytical chemistry and biochemical/biophysical research, where measurements of ionic concentration in an aqueous solution are required.

Property Value
dbo:abstract
  • An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a transducer (or sensor) that converts the activity of a specific ion dissolved in a solution into an electrical potential. The voltage is theoretically dependent on the logarithm of the ionic activity, according to the Nernst equation. Ion-selective electrodes are used in analytical chemistry and biochemical/biophysical research, where measurements of ionic concentration in an aqueous solution are required. (en)
  • Un electrodo selectivo de iones (ISE por sus sigla en inglés), también denominado electrodo para iones epecíficos (SIE), es un transductor (o sensor) que convierte la actividad de un ión específico disuelto en una solución en un potencial eléctrico, el cual se puede medir con un voltímetro o PH-metro. Teóricamente el voltaje depende del logaritmo de la actividad iónica, de acuerdo con la ecuación de Nernst. La parte sensora del electrodo es por lo general una membrana específica para el ión, junto con un electrodo de referencia. Los electrodos selectivos de iones son utilizados en investigaciones en el ámbito de la bioquímica y biofísica, donde es preciso conocer las concentraciones iónicas en una solución acuosa, por lo general en tiempo real. (es)
  • Eine ionenselektive Elektrode, auch ionenspezifische oder ionensensitive Elektrode (ISE) genannt, dient als Sensor für die Konzentration oder genauer die Aktivität eines bestimmten gelösten Ions. Für die Messung taucht man die ionenselektive Elektrode und eine zweite Elektrode, die Bezugselektrode, in die Messlösung und misst die Spannung zwischen den Elektroden. Daraus kann man dann die gesuchte Konzentration bestimmen. Die Messgröße ist also eine konzentrationsabhängige Spannung gegen die Bezugselektrode. Diese Spannung hängt nach der Nernstgleichung logarithmisch von der Aktivität des betreffenden Ions ab. Die bekannteste ionenselektive Elektrode ist die pH-Elektrode, die auf Protonen (Wasserstoff- oder Hydroniumionen) anspricht. Ionenselektive Elektroden werden in vielen Bereichen eingesetzt, z.B. in der analytischen Chemie einschließlich der Umweltanalytik, in biochemischer und biophysikalischer Forschung und in industriellen Prozessen. Es wird geschätzt, dass in klinischen Laboratorien jedes Jahr weit über eine Milliarde Analysen mit ionenselektiven Elektroden ausgeführt werden, so dass die medizinische Untersuchungen heute die wichtigste Routineanwendung von ionenselektiven Elektroden sind. (de)
  • Un elettrodo a membrana, definito anche elettrodo ionoselettivo, è un elettrodo cilindrico in grado di misurare la concentrazione di una specifica specie chimica ionica o anche molecolare: questa peculiare sensibilità rappresenta la caratteristica saliente di questa classe di elettrodi. Schematicamente gli elettrodi a membrana sono costituiti da un involucro che racchiude un sensore metallico immerso in una soluzione di riferimento a concentrazione nota e costante. La parte sensibile è costituita da una piccola membrana sita sul fondo dell'elettrodo tra le cui interfacce interna ed esterna si stabilisce una differenza di potenziale dovuta alla differenza di concentrazione esistente tra la soluzione di riferimento e quella contenente l'analita e nelle quali è immerso l'elettrodo a membrana. Il funzionamento dell'elettrodo ionoselettivo è descritto dall'equazione di Nicolskij-Pungor-Eisenman, generalizzazione della più nota equazione di Nernst: dove: * E0 è una costante di elettrodo; * ai l'attività dell'analita; * Kj il coefficiente di selettività dell'elettrodo; * aj l'attività della specie j-esima presente in soluzione e verso la quale l'elettrodo presenta una più o meno marcata sensibilità; * n è la carica ionica dell'analita e nj la carica della specie j-esima di cui sopra. Il coefficiente di selettività indica il livello di specificità dell'elettrodo a membrana e varia da valori di 10-13, tipici degli elettrodi a vetro, a valori compresi tra 10-4 - 10-7 per altri elettrodi selettivi. Esistono diverse tipologie di membrane che si differenziano sia in base al loro stato fisico sia in base alla loro composizione chimica: 1. * Membrane solide 2. 1. * A vetro, utilizzate ad esempio per determinare ioni Na+ e H+ 3. 2. * Cristalline, come quelle sensibili a ioni quali F-, Pb2+ e Cu2+ 4. 3. * Resine a scambio ionico, selettive ad esempio verso il potassio e diversi cationi ed anioni 5. * Membrane liquide, formate da soluzioni di composti organici in solventi immiscibili con l'acqua e supportate su di un solido 6. * Elettrodi ad enzima, formato da una membrana contenente un enzima il cui prodotto di reazione (solitamente ioni H+ o OH-) viene misurato dal reale elettrodo ionoselettivo ricoperto dalla precedente membrana (un esempio è l'elettrodo glucosio selettivo) Gli elettrodi a membrana si prestano sia a misure potenziometriche dirette che indirette, ma la loro minore selettività rispetto ai classici elettrodi richiede particolare attenzione per le possibili interferenze. Richiedono inoltre una costante calibrazione e molta cura nell'utilizzazione. La ricerca attuale è rivolta allo sviluppo di elettrodi a membrana più specifici e selettivi, oltre che all'ampliamento delle possibili specie chimiche analizzabili. Gli elettrodi a membrana sono utilizzati negli analizzatori della medicina di laboratorio per misurare gli elettroliti contenuti nel sangue. (it)
  • Elektroda jonoselektywna (ang. Ion-Selective Electrode, ISE) – elektroda, której potencjał względem elektrody odniesienia, zmienia się pod wpływem zmian aktywności jonów w badanym roztworze. Najpowszechniej używanymi elektrodami jonoselektywnymi są elektrody wskaźnikowe stosowane w pH-metrii, czułe na jony wodorowe (H+). Najprostszym modelem matematycznym elektrody jonoselektywnej jest równanie Nernsta: w którym: * E – potencjał elektrody jonoselektywnej, * R – stała gazowa, * T – temperatura bezwzględna, * z – liczba ładunków elementarnych jonu, * F – stała Faradaya, * a – aktywność jonu, * ln – symbol logarytmu naturalnego. Bardzo często przyjmuje się, że wartość aktywności jest równa wartości stężenia jonu, co daje zadowalające przybliżenie dla dużej grupy zastosowań. W rzeczywistości aktywność ze stężeniem powiązana jest poprzez współczynnik aktywności. (pl)
  • Een ionselectieve elektrode (ISE) is een elektrochemische sensor die voor een of meer specifieke ionen veel gevoeliger is dan voor andere ionen. Voor elk te meten ion is er een eigen selectieve elektrode. De werking van een ionselectieve elektrode is gebaseerd op het meten van potentiaalverschil tussen twee elektroden. Zodra de elektroden in een monster (bijvoorbeeld lichaamsvochten als bloed of urine) geplaatst worden, vergelijkt de gekoppelde elektronica het potentiaalverschil met een standaardwaarde. De grootte hiervan correleert met de concentratie van elektrolyten in het monster. Deze methode wordt potentiometrie genoemd. (nl)
dbo:wikiPageExternalLink
dbo:wikiPageID
  • 593406 (xsd:integer)
dbo:wikiPageRevisionID
  • 741497076 (xsd:integer)
dct:subject
http://purl.org/linguistics/gold/hypernym
rdf:type
rdfs:comment
  • An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a transducer (or sensor) that converts the activity of a specific ion dissolved in a solution into an electrical potential. The voltage is theoretically dependent on the logarithm of the ionic activity, according to the Nernst equation. Ion-selective electrodes are used in analytical chemistry and biochemical/biophysical research, where measurements of ionic concentration in an aqueous solution are required. (en)
  • Un electrodo selectivo de iones (ISE por sus sigla en inglés), también denominado electrodo para iones epecíficos (SIE), es un transductor (o sensor) que convierte la actividad de un ión específico disuelto en una solución en un potencial eléctrico, el cual se puede medir con un voltímetro o PH-metro. Teóricamente el voltaje depende del logaritmo de la actividad iónica, de acuerdo con la ecuación de Nernst. La parte sensora del electrodo es por lo general una membrana específica para el ión, junto con un electrodo de referencia. Los electrodos selectivos de iones son utilizados en investigaciones en el ámbito de la bioquímica y biofísica, donde es preciso conocer las concentraciones iónicas en una solución acuosa, por lo general en tiempo real. (es)
  • Eine ionenselektive Elektrode, auch ionenspezifische oder ionensensitive Elektrode (ISE) genannt, dient als Sensor für die Konzentration oder genauer die Aktivität eines bestimmten gelösten Ions. Für die Messung taucht man die ionenselektive Elektrode und eine zweite Elektrode, die Bezugselektrode, in die Messlösung und misst die Spannung zwischen den Elektroden. Daraus kann man dann die gesuchte Konzentration bestimmen. (de)
  • Un elettrodo a membrana, definito anche elettrodo ionoselettivo, è un elettrodo cilindrico in grado di misurare la concentrazione di una specifica specie chimica ionica o anche molecolare: questa peculiare sensibilità rappresenta la caratteristica saliente di questa classe di elettrodi. dove: Il coefficiente di selettività indica il livello di specificità dell'elettrodo a membrana e varia da valori di 10-13, tipici degli elettrodi a vetro, a valori compresi tra 10-4 - 10-7 per altri elettrodi selettivi. (it)
  • Elektroda jonoselektywna (ang. Ion-Selective Electrode, ISE) – elektroda, której potencjał względem elektrody odniesienia, zmienia się pod wpływem zmian aktywności jonów w badanym roztworze. Najpowszechniej używanymi elektrodami jonoselektywnymi są elektrody wskaźnikowe stosowane w pH-metrii, czułe na jony wodorowe (H+). Najprostszym modelem matematycznym elektrody jonoselektywnej jest równanie Nernsta: w którym: (pl)
  • Een ionselectieve elektrode (ISE) is een elektrochemische sensor die voor een of meer specifieke ionen veel gevoeliger is dan voor andere ionen. Voor elk te meten ion is er een eigen selectieve elektrode. (nl)