Chronaxie is the minimum time required for an electric current double the strength of the rheobase to stimulate a muscle or a neuron. Rheobase is the lowest intensity with indefinite pulse duration which just stimulated muscles or nerves. Chronaxie is dependent on the density of voltage-gated sodium channels in the cell, which affect that cell’s excitability. Chronaxie varies across different types of tissue: fast-twitch muscles have a lower chronaxie, slow-twitch muscles have a higher one. Chronaxie is the tissue-excitability parameter thatpermits choice of the optimum stimulus pulse duration for stimulation of any excitable tissue. Chronaxie (c) is the Lapicque descriptor of the stimulus pulse duration for a currentof twice rheobasic (b) strength, which is the threshold currentfor an inf

Property Value
dbo:abstract
  • Als Chronaxie bezeichnet man die minimale Zeit, über die ein Reiz mit doppelter Rheobasestärke fließen muss, um gerade noch erregend zu wirken. Im Gegenteil dazu bezeichnet die Hauptnutzzeit die Mindestzeit, die ein Strom bei (einfacher) Rheobasestärke fließen muss, um ein Aktionspotential auszulösen. Sowohl Chronaxie als auch die Hauptnutzzeit sind Nutzzeiten. Es wird also die Länge der bei doppelter Stärke für eine Kontraktion benötigte Zeit gemessen. Der Begriff findet Verwendung in der Physiotherapie bei der niederfrequenten Impulsstrom-Therapie. Eine Erregung kann an einer erregbaren Struktur (beispielsweise peripherer Nerv oder Muskel) durch elektrisches Reizen erzeugt werden. Ist die Stärke des Stromes ausreichend hoch, wird ein Aktionspotential ausgelöst. Reizt man jedoch zu niedrig, erfolgt keine Reaktion der Struktur (der Reiz ist „unterschwellig“). Um die Ansprechbarkeit eines solchen Gewebes präzise zu beschreiben, nutzt man die Begriffe Rheobase und Chronaxie, welche die Beziehung von erforderlicher Reizstärke und Reizzeit vermitteln. (de)
  • 45xCe modèle est-il pertinent ? Cliquez pour en voir d'autres.Cet article ne cite pas suffisamment ses sources (juin 2015). Si vous disposez d'ouvrages ou d'articles de référence ou si vous connaissez des sites web de qualité traitant du thème abordé ici, merci de compléter l'article en donnant les références utiles à sa vérifiabilité et en les liant à la section « Notes et références » (modifier l'article, comment ajouter mes sources ?). La chronaxie, dans le cadre de la description mathématique du fonctionnement du système nerveux, est la durée nécessaire pour stimuler une fibre musculaire, ou une cellule nerveuse avec un courant électrique d'intensité égale au double de la rhéobase. Ce terme a été inventé en 1909 par le physiologiste français Louis Lapicque. C'est à Georges Bourguignon (1876-1963) que l'on doit les premières applications cliniques de la chronaxie. La chronaxie d'un axone myélinisé dans le cerveau est de 30 à 200 microsecondes[réf. souhaitée] alors que la chronaxie des dendrites et des corps cellulaires des neurones est de 1 à 10 millisecondes[réf. souhaitée]. "On passe ainsi d’une vitesse de conduction de 1-10 m/s dans les fibres amyéliniques jusqu’à 150 m/s dans les motoneurones α myélinisés de gros calibre" dixit J-M MIENVILLE dans "Neurobiologie", page 6, paragraphe "propagation du PA" (). (fr)
  • En la descripción matemática que se hace del sistema nervioso, se denomina cronaxia (o cronaxy) al intervalo de tiempo que debe aplicarse una corriente eléctrica para conseguir una respuesta mínima con una intensidad doble de la reobase (respuesta motora o sensitiva, aunque habitualmente se hace referencia a la motora). El término "cronaxia" y "reobase" fue acuñado en 1909 por el fisiólogo francés Louis Lapicque. Es por lo tanto una medición de la excitabilidad del tejido nervioso o muscular. Se denomina igualmente tiempo de utilización al tiempo necesario para que la reobase tenga efecto. (es)
  • Chronaxie is the minimum time required for an electric current double the strength of the rheobase to stimulate a muscle or a neuron. Rheobase is the lowest intensity with indefinite pulse duration which just stimulated muscles or nerves. Chronaxie is dependent on the density of voltage-gated sodium channels in the cell, which affect that cell’s excitability. Chronaxie varies across different types of tissue: fast-twitch muscles have a lower chronaxie, slow-twitch muscles have a higher one. Chronaxie is the tissue-excitability parameter thatpermits choice of the optimum stimulus pulse duration for stimulation of any excitable tissue. Chronaxie (c) is the Lapicque descriptor of the stimulus pulse duration for a currentof twice rheobasic (b) strength, which is the threshold currentfor an infinitely long-duration stimulus pulse. Lapicque showedthat these two quantities (c,b) define the strength-duration curvefor current: I = b(1+c/d), where d is the pulse duration.However, there are two other electrical parameters used todescribe a stimulus: energy and charge. The minimum energyoccurs with a pulse duration equal to chronaxie. Minimumcharge (bc) occurs with an infinitely short-duration pulse.Choice of a pulse duration equal to 10c requires a current ofonly 10% above rheobase (b). Choice of a pulse duration of0.1c requires a charge of 10% above the minimum charge (bc). (en)
  • Хронаксия (от др.-греч. χρόνος — «время» и ἀξία — «цена», «мера») — минимальное время, требуемое для возбуждения мышечной либо нервной ткани постоянным электрическим током удвоенной пороговой силы (реобаза). Понятие «хронаксия» введено французским физиологом Луисом Лапиком в 1909 году. Измерение хронаксии — хронаксиметрия — применяется для изучения работы нервного и двигательного аппарата человека и животных. (ru)
dbo:thumbnail
dbo:wikiPageID
  • 5233392 (xsd:integer)
dbo:wikiPageRevisionID
  • 733402607 (xsd:integer)
dct:subject
http://purl.org/linguistics/gold/hypernym
rdf:type
rdfs:comment
  • En la descripción matemática que se hace del sistema nervioso, se denomina cronaxia (o cronaxy) al intervalo de tiempo que debe aplicarse una corriente eléctrica para conseguir una respuesta mínima con una intensidad doble de la reobase (respuesta motora o sensitiva, aunque habitualmente se hace referencia a la motora). El término "cronaxia" y "reobase" fue acuñado en 1909 por el fisiólogo francés Louis Lapicque. Es por lo tanto una medición de la excitabilidad del tejido nervioso o muscular. Se denomina igualmente tiempo de utilización al tiempo necesario para que la reobase tenga efecto. (es)
  • Хронаксия (от др.-греч. χρόνος — «время» и ἀξία — «цена», «мера») — минимальное время, требуемое для возбуждения мышечной либо нервной ткани постоянным электрическим током удвоенной пороговой силы (реобаза). Понятие «хронаксия» введено французским физиологом Луисом Лапиком в 1909 году. Измерение хронаксии — хронаксиметрия — применяется для изучения работы нервного и двигательного аппарата человека и животных. (ru)
  • Als Chronaxie bezeichnet man die minimale Zeit, über die ein Reiz mit doppelter Rheobasestärke fließen muss, um gerade noch erregend zu wirken. Im Gegenteil dazu bezeichnet die Hauptnutzzeit die Mindestzeit, die ein Strom bei (einfacher) Rheobasestärke fließen muss, um ein Aktionspotential auszulösen. Sowohl Chronaxie als auch die Hauptnutzzeit sind Nutzzeiten. Es wird also die Länge der bei doppelter Stärke für eine Kontraktion benötigte Zeit gemessen. Der Begriff findet Verwendung in der Physiotherapie bei der niederfrequenten Impulsstrom-Therapie. (de)
  • Chronaxie is the minimum time required for an electric current double the strength of the rheobase to stimulate a muscle or a neuron. Rheobase is the lowest intensity with indefinite pulse duration which just stimulated muscles or nerves. Chronaxie is dependent on the density of voltage-gated sodium channels in the cell, which affect that cell’s excitability. Chronaxie varies across different types of tissue: fast-twitch muscles have a lower chronaxie, slow-twitch muscles have a higher one. Chronaxie is the tissue-excitability parameter thatpermits choice of the optimum stimulus pulse duration for stimulation of any excitable tissue. Chronaxie (c) is the Lapicque descriptor of the stimulus pulse duration for a currentof twice rheobasic (b) strength, which is the threshold currentfor an inf (en)
  • 45xCe modèle est-il pertinent ? Cliquez pour en voir d'autres.Cet article ne cite pas suffisamment ses sources (juin 2015). Si vous disposez d'ouvrages ou d'articles de référence ou si vous connaissez des sites web de qualité traitant du thème abordé ici, merci de compléter l'article en donnant les références utiles à sa vérifiabilité et en les liant à la section « Notes et références » (modifier l'article, comment ajouter mes sources ?). (fr)
rdfs:label
  • Chronaxie (de)
  • Chronaxie (en)
  • Cronaxia (es)
  • Chronaxie (fr)
  • Хронаксия (ru)
owl:sameAs
prov:wasDerivedFrom
foaf:depiction
foaf:isPrimaryTopicOf
is dbo:wikiPageRedirects of
is foaf:primaryTopic of